Accuracy of biplane long-axis left ventricular volume determined by cine magnetic resonance imaging in patients with regional and global dysfunction

被引:44
作者
Lawson, MA
Blackwell, GG
Davis, ND
Roney, M
DellItalia, LJ
Pohost, GM
机构
[1] Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, AL
[2] Univ. Alabama at Birmingham, 311 THT, Birmingham, AL 35294
关键词
D O I
10.1016/S0002-9149(96)00140-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Loft ventricular (LV) volumes and election fraction can be obtained by applying Simpson's rule to multiple short-axis tomographic planes. A simpler method for determining LV volumes using the area-length equation is widely accepted and requires less time to acquire and analyze, Ifs accuracy, however, is questionable in deformed or asymmetrically contracting ventricles, This study compares biplane long-axis to serial short-axis computed LV volumes obtained by cine gradient-echo magnetic resonance imaging (MRI) in 2 distinct patient populations: (If patients with global LV dysfunction, and (2) patients with regional LV dysfunction. A total of 114 patients were studied using both methods, Among 37 patients with global LV dysfunction, there was no statistically significant difference between methods (long axis vs short axis] for determining LV end-diastolic volume (203 +/- 91 vs 201 +/- 90 ml), end-systolic volume (142 +/- 81 vs 141 +/- 82 ml), and ejection fraction (33 +/- 12 vs 33 +/- 13%), However, in the 77 patients with regional dysfunction, LV end-diastolic volume was statistically slightly higher when obtained using the long-axis approach (157 +/- 53 vs 152 +/- 51 ml; p=0.004), Otherwise, end-systolic volume (97 +/- 49 vs 95 +/- 49 ml) and election fraction (40 +/- 13 vs 40 +/- 13%) were similar (p=NS), The correlation between LV volumes and election fractions for bath groups was excellent (r >0.91). Thus, in this study group, biplane long-axis and serial short-axis computed LV volumes and election fractions were similar in patients with global or regional LV dysfunction, In critically ill patients unable to complete a comprehensive MRI examination, the biplane long-axis-derived volumes provide adequate data.
引用
收藏
页码:1098 / 1104
页数:7
相关论文
共 26 条
[1]   CONTRAST AGENTS FOR CARDIAC-CATHETERIZATION - CONCEPTIONS AND MISCONCEPTIONS [J].
BROGAN, WC ;
HILLIS, LD ;
LANGE, RA .
AMERICAN HEART JOURNAL, 1991, 122 (04) :1129-1135
[2]   GATED CARDIAC MRI - EJECTION-FRACTION DETERMINATION USING THE RIGHT ANTERIOR OBLIQUE VIEW [J].
BUCKWALTER, KA ;
AISEN, AM ;
DILWORTH, LR ;
MANCINI, GBJ ;
BUDA, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (01) :33-37
[3]   ANALYSIS OF LEFT-VENTRICULAR FUNCTION FROM MULTIPLE GATED ACQUISITION CARDIAC BLOOD POOL IMAGING - COMPARISON TO CONTRAST ANGIOGRAPHY [J].
BUROW, RD ;
STRAUSS, HW ;
SINGLETON, R ;
POND, M ;
REHN, T ;
BAILEY, IK ;
GRIFFITH, LC ;
NICKOLOFF, E ;
PITT, B .
CIRCULATION, 1977, 56 (06) :1024-1028
[4]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[5]   DETERMINATION OF LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION BY NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
DILWORTH, LR ;
AISEN, AM ;
MANCINI, GBJ ;
LANDE, I ;
BUDA, AJ .
AMERICAN HEART JOURNAL, 1987, 113 (01) :24-32
[6]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[7]   ASSESSMENT OF LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES BY REAL-TIME, 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON OF CINEANGIOGRAPHIC AND RADIONUCLIDE TECHNIQUES [J].
FOLLAND, ED ;
PARISI, AF ;
MOYNIHAN, PF ;
JONES, DR ;
FELDMAN, CL ;
TOW, DE .
CIRCULATION, 1979, 60 (04) :760-766
[8]   EFFECTS OF ANGIOGRAPHIC CONTRAST MEDIA ON CARDIAC FUNCTION [J].
GOOTMAN, N ;
RUDOLPH, AM ;
BUCKLEY, NM .
AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (01) :59-&
[9]   LEFT-VENTRICULAR VOLUMES BY SINGLE-PLANE CINEANGIOGRAPHY - INVIVO VALIDATION OF THE KENNEDY REGRESSION EQUATION [J].
HILLIS, LD ;
WINNIFORD, MD ;
DEHMER, GJ ;
FIRTH, BG .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (08) :1159-1163
[10]   LEFT VENTRICULAR VOLUME AND MASS FROM SINGLE-PLANE CINEANGIOCARDIOGRAM - A COMPARISON OF ANTEROPOSTERIOR AND RIGHT ANTERIOR OBLIQUE METHODS [J].
KENNEDY, JW ;
TRENHOLME, SE ;
KASSER, IS .
AMERICAN HEART JOURNAL, 1970, 80 (03) :343-+