The performance of crystalline silicon photovoltaic solar modules after 22 years of continuous outdoor exposure

被引:114
作者
Dunlop, ED [1 ]
Halton, D [1 ]
机构
[1] Commiss European Communities, DG Joint Res Ctr, Inst Environm & Sustainabil Renewable Energies Un, I-21020 Ispra, VA, Italy
来源
PROGRESS IN PHOTOVOLTAICS | 2006年 / 14卷 / 01期
关键词
lifetime; reliability; degradation; durability; encapsulant; weathering; EVA; solar electricity;
D O I
10.1002/pip.627
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results of 40 silicon-based photovoltaic solar modules originating from six different manufactures which were tested and characterised originally at the European Solar Test Installation, (ESTI), in the period 1982-1984. These same modules have been re-measured in 2004 after 20-22 years of continuous outdoor weathering. These modules are a subset 'Rack C' of the JRC Ispra outdoor test field where examples of diverse generations of PV technologies have been subjected to long-term climatic exposure. We have compared the results obtained from these samples with the typical guarantees which are given by module manufacturers and we can see that in general the manufacturers are conservative with their power guarantees. Most modules exceed the minimum power levels given for 10 years exposure, even after 22 years in the field. The results presented in this paper indicate that the degradation observed in the field is comparable to that observed in Type Approval Testing. This result not only validates the testing and stress levels applied in the Type Approval Tests, but also would indicate that (with the majority of modules exceeding the level of 92% of P-max after 20 years) the actual lifetime of these products is significantly more than 20 years. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 6 条
[1]  
Dunlop ED, 2003, WORL CON PHOTOVOLT E, P2927
[2]  
*EUR COMM, 1981, 501 CEC
[3]  
Ossenbrink H, 2003, WORL CON PHOTOVOLT E, P1882
[4]   Commonly observed degradation in field-aged photovoltaic modules [J].
Quintana, MA ;
King, DL ;
McMahon, TJ ;
Osterwald, CR .
CONFERENCE RECORD OF THE TWENTY-NINTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE 2002, 2002, :1436-1439
[5]  
Realini A, 2001, 17 EUR PHOT SOL EN C, P447
[6]   Comparison of PV module performance before and after 11-years of field exposure [J].
Reis, AM ;
Coleman, NT ;
Marshall, MW ;
Lehman, PA ;
Chamberlin, CE .
CONFERENCE RECORD OF THE TWENTY-NINTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE 2002, 2002, :1432-1435