Prevention of hemolysis in blood samples collected from intravenous catheters

被引:36
作者
Lippi, Giuseppe [1 ]
Avanzini, Paola [1 ]
Cervellin, Gianfranco [2 ]
机构
[1] Acad Hosp Parma, Lab Clin Chem & Hematol, Parma, Italy
[2] Acad Hosp Parma, Emergency Dept, Parma, Italy
关键词
Hemolysis; Catheters; Blood collection; Venipuncture; Quality; CLINICAL LABORATORIES; QUALITY IMPROVEMENT; SPECIMENS; MANAGEMENT; CHALLENGE; CHEMISTRY; RATES; TUBES;
D O I
10.1016/j.clinbiochem.2013.01.021
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Samples drawn through intravenous catheters are frequently hemolyzed. We planned a prospective, randomized study to establish whether hemolysis in samples drawn from intravenous catheters may be reduced using S-Monovette (R) tubes collected by manual aspiration as compared with standard vacuum tubes. Design and Methods: We studied 52 consecutive patients admitted to the ED. Blood was drawn through a 20-gauge intravenous catheter. A 5.0 mL, Becton Dickinson Vacutainer (R) SST II Plus serum tube was collected and discarded. In the odd group of patients (i.e., n. 1, 3, 5, etc.), a second SST II tube was drawn with vacuum ("BD-V"), followed by a 5.5 mL 5-Monovette (R) serum tube collected with manual aspiration ("SD-A") and an identical S-Monovette collected by vacuum ("SD-V"). In the pair group of patients (i.e., n. 2, 4, 6, etc.), the sequence was modified to "SD-A", "SD-V" and "BD-V". Serum was separated and tested for lactate dehydrogenase (LDH), potassium and cell-free hemoglobin. Results: The mean concentration of potassium (+2.7% in BD-V and + 1.7% in SD-V, respectively), LDH (+15% in BD-V and + 7% in SD-V, respectively) and cell-free hemoglobin was significantly increased when samples were collected with vacuum tubes as compared with manual aspiration. No significant differences were observed between SD-V and BD-V. The frequency of hemolyzed samples was higher when blood was collected with the vacuum as compared with SD-A (i.e., 2%), but did not differ between BD-V and SD-V (i.e., 29 versus 31%; p = 0.70). Conclusion: S-Monovette can be used with vacuum or aspiration collection. This latter approach allows blood drawing with limited shear stress and less likelihood of generating spuriously hemolysis. (C) 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 20 条
[1]  
Carraro P, 2000, CLIN CHEM, V46, P306
[2]  
Cox Sandra R, 2004, J Emerg Nurs, V30, P529, DOI 10.1016/j.jen.2004.10.004
[3]  
Grant Marian Sue, 2003, J Emerg Nurs, V29, P116, DOI 10.1067/men.2003.66
[4]   OBTAINING BLOOD SAMPLES FROM PERIPHERAL INTRAVENOUS CATHETERS: BEST PRACTICE? [J].
Halm, Margo A. ;
Gleaves, Melissa .
AMERICAN JOURNAL OF CRITICAL CARE, 2009, 18 (05) :474-478
[5]   Preanalytical management: serum vacuum tubes validation for routine clinical chemistry [J].
Lima-Oliveira, Gabriel ;
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Montagnana, Martina ;
Picheth, Geraldo ;
Guidi, Gian Cesare .
BIOCHEMIA MEDICA, 2012, 22 (02) :180-186
[6]   Preanalytical variability: the dark side of the moon in laboratory testing [J].
Lippi, G ;
Guidi, GC ;
Mattiuzzi, C ;
Plebani, M .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) :358-365
[7]   Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories [J].
Lippi, Giuseppe ;
Blanckaert, Norbert ;
Bonini, Pierangelo ;
Green, Sol ;
Kitchen, Steve ;
Palicka, Vladimir ;
Vassault, Anne J. ;
Plebani, Mario .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (06) :764-772
[8]   Recommendations for detection and management of unsuitable samples in clinical laboratories [J].
Lippi, Giuseppe ;
Banfi, Giuseppe ;
Buttarello, Mauro ;
Ceriotti, Ferruccio ;
Daves, Massimo ;
Dolci, Alberto ;
Caputo, Marco ;
Giavarina, Davide ;
Montagnana, Martina ;
Micon, Valentino ;
Milanesi, Bruno ;
Mosca, Andrea ;
Morandini, Margherita ;
Luca, Gian .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (06) :728-736
[9]  
Lippi Giuseppe, 2006, MLO Med Lab Obs, V38, P6
[10]   Evaluation of the analytical performances of the novel Beckman Coulter AU5800 [J].
Lippi, Giuseppe ;
Dipalo, Mariella ;
Musa, Roberta ;
Avanzini, Paola ;
Ferrarini, Cinzia ;
Pattini, Antonio ;
Aloe, Rosalia .
CLINICAL BIOCHEMISTRY, 2012, 45 (06) :502-504