On-line microdialysis of proteins with high-salt buffers for direct coupling of electrospray ionization mass spectrometry and liquid chromatography

被引:30
作者
Canarelli, S [1 ]
Fisch, I [1 ]
Freitag, R [1 ]
机构
[1] Swiss Fed Inst Technol, Lab Chem Biotechnol, Ctr Biotechnol, CH-1015 Lausanne, Ecublens, Switzerland
关键词
electrospray ionization; interfaces; LC-MS; microdialysis; proteins;
D O I
10.1016/S0021-9673(01)01344-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometry (MS) is one of the most powerful instrumental techniques for protein analysis. The electrospray ionization (ESI) approach is known to be very gentle and at the same time compatible with liquid separation techniques such as HPLC and CE. However, ESI is known to be susceptible to salts and impurities, which often cause a dramatic decrease in sensitivity due to the suppression of the ionization of the product of interest. For this reason, LC-ESI-MS coupling has so far been largely limited to reversed-phase chromatography with its hydro-organic mobile phases. Other chromatographic techniques are typically "linked" to ESI-MS by time consuming, off-line desalting steps. On-line microdialysis has been proposed as a solution to this dilemma. In this paper, we introduce an improved microdialysis system, which enlarges the number of putative applications, thus allowing chromatographic separations of biological compounds to be directly coupled to MS detection with little to no loss in time or chromatographic resolution. Examples include separations by affinity, ion-exchange and size-exclusion chromatography, all of which were connected successfully to the ESI-MS detector via the on-line microdialyzer. We propose that, using this system, any kind of chromatography technique can be coupled to ESI-MS, thus enabling for example application in quality control or process monitoring of many bioproduction and downstream processes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 13 条
[1]   Advances in sample preparation in electromigration, chromatographic and mass spectrometric separation methods [J].
Gilar, M ;
Bouvier, ESP ;
Compton, BJ .
JOURNAL OF CHROMATOGRAPHY A, 2001, 909 (02) :111-135
[2]   Isolation of a recombinant antibody from cell culture supernatant: Continuous annular versus batch and expanded-bed chromatography [J].
Giovannini, R ;
Freitag, R .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 73 (06) :522-529
[3]   Mass determination of oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry following HPLC, assisted by on-line desalting and automated sample handling [J].
Kabel, MA ;
Schols, HA ;
Voragen, AGJ .
CARBOHYDRATE POLYMERS, 2001, 44 (02) :161-165
[4]   On-line microdialysis for mass spectrometry [J].
Konig, S ;
Weiler, S ;
Fales, HM .
BIOTECHNIQUES, 1998, 24 (05) :712-+
[5]   Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry [J].
Linnemayr, K ;
Rizzi, A ;
Josic, D ;
Allmaier, G .
ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) :187-199
[6]   Direct coupling of ionic high-performance liquid chromatography with electrospray ionization mass spectrometry utilizing a microdialysis junction interface [J].
Liu, CL ;
Verma, SS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :93-104
[7]   On line microdialysis sample cleanup for electrospray ionization mass-spectrometry of nucleic acid samples [J].
Liu, CL ;
Wu, QY ;
Harms, AC ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3295-3299
[8]   On line dual microdialysis with ESI-MS for direct analysis of complex biological samples and microorganism lysates [J].
Liu, CL ;
Hofstadler, SA ;
Bresson, JA ;
Udseth, HR ;
Tsukuda, T ;
Smith, RD ;
Snyder, AP .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1797-1801
[9]   CHO expression of a novel human recombinant IgG1 anti-RhD antibody isolated by phage display [J].
Miescher, S ;
Zahn-Zabal, M ;
De Jesus, M ;
Moudry, R ;
Fisch, I ;
Vogel, M ;
Kobr, M ;
Imboden, MA ;
Kragten, E ;
Bichler, J ;
Mermod, N ;
Stadler, BM ;
Amstutz, H ;
Wurm, F .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 111 (01) :157-166
[10]   Microcolumn size-exclusion chromatography coupled with electrospray ionization mass spectrometry [J].
Prokai, L ;
Aaserud, DJ ;
Simonsick, WJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :121-126