Sample concentration and impedance detection on a microfluidic polymer chip

被引:77
作者
Sabounchi, Poorya [1 ,2 ]
Morales, Alfredo M. [3 ]
Ponce, Pierre [1 ]
Lee, Luke P. [2 ]
Simmons, Blake A. [1 ]
Davalos, Rafael V. [4 ]
机构
[1] Sandia Natl Labs, Energy Syst Dept, Livermore, CA USA
[2] Univ Calif Berkeley, Berkeley Sensor & Actuator Ctr, Dept Bioengn, Berkeley, CA 94720 USA
[3] Sandia Natl Labs, Dept Chem Mat, Livermore, CA USA
[4] Virginia Tech Wake Forest Univ, Sch Biomed Engn & Sci, Blacksburg, VA USA
关键词
dielectrophoresis; insulator-based dielectrophoresis; biochip; sample enrichment; pathogen monitoring; BioMEMS;
D O I
10.1007/s10544-008-9177-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present an on-chip microfluidic sample concentrator and detection triggering system for microparticles based on a combination of insulator-based dielectrophoresis (iDEP) and electrical impedance measurement. This platform operates by first using iDEP to selectively concentrate microparticles of interest based on their electrical and physiological characteristics in a primary fluidic channel; the concentrated microparticles are then directed into a side channel configured for particle detection using electrical impedance measurements with embedded electrodes. This is the first study showing iDEP concentration with subsequent sample diversion down an analysis channel and is the first to demonstrate iDEP in the presence of pressure driven flow. Experimental results demonstrating the capabilities of this platform were obtained using polystyrene microspheres and Bacillus subtilis spores. The feasibility of selective iDEP trapping and impedance detection of these particles was demonstrated. The system is intended for use as a front-end unit that can be easily paired with multiple biodetection/bioidentification systems. This platform is envisioned to act as a decision-making component to determine if confirmatory downstream identification assays are required. Without a front end component that triggers downstream analysis only when necessary, bio-identification systems (based on current analytical technologies such as PCR and immunoassays) may incur prohibitively high costs to operate due to continuous consumption of expensive reagents.
引用
收藏
页码:661 / 670
页数:10
相关论文
共 53 条
  • [31] Dielectrophoretic concentration and separation of live and dead bacteria in an array of insulators
    Lapizco-Encinas, BH
    Simmons, BA
    Cummings, EB
    Fintschenko, Y
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (06) : 1571 - 1579
  • [32] Pathogen detection:: A perspective of traditional methods and biosensors
    Lazcka, Olivier
    Del Campo, F. Javier
    Munoz, F. Xavier
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) : 1205 - 1217
  • [33] HIGH-INTENSITY, HIGH-GRADIENT ELECTRIC SEPARATION AND DIELECTRIC FILTRATION OF PARTICULATE AND GRANULAR-MATERIALS
    LIN, IJ
    BENGUIGUI, L
    [J]. JOURNAL OF ELECTROSTATICS, 1982, 13 (03) : 257 - 278
  • [34] Linderholm P, 2005, LAB CHIP, V5, P1416, DOI 10.1039/b5l2077b
  • [35] Electrical detection of germination of viable model Bacillus anthracis spores in microfluidic biochips
    Liu, Yi-Shao
    Walter, T. M.
    Chang, Woo-Jin
    Lim, Kwan-Seop
    Yang, Liju
    Lee, S. W.
    Aronson, A.
    Bashir, R.
    [J]. LAB ON A CHIP, 2007, 7 (05) : 603 - 610
  • [36] Maxwell JC, 1873, TREATISE ELECT MAGNE
  • [37] High speed simultaneous single particle impedance and fluorescence analysis on a chip
    Morgan, Hywel
    Holmes, David
    Green, Nicolas G.
    [J]. CURRENT APPLIED PHYSICS, 2006, 6 (03) : 367 - 370
  • [38] Effective conductivity of a suspension of permeabilized cells: A theoretical analysis
    Pavlin, M
    Miklavcic, D
    [J]. BIOPHYSICAL JOURNAL, 2003, 85 (02) : 719 - 729
  • [39] Effective conductivity of cell suspensions
    Pavlin, M
    Slivnik, T
    Miklavcic, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (01) : 77 - 80
  • [40] Pohl, 1978, DIELECTROPHORESIS