Mechanical behavior of coronary stents investigated through the finite element method

被引:274
作者
Migliavacca, F
Petrini, L
Colombo, M
Auricchio, F
Pietrabissa, R
机构
[1] Politecn Milan, Dipartimento Bioingn, Lab Biol Struct Mech, I-20133 Milan, Italy
[2] Univ Pavia, Dipartimento Meccan Strutturale, I-27100 Pavia, Italy
关键词
coronary stent; finite element method; numerical simulations; mechanical response; mathematical model;
D O I
10.1016/S0021-9290(02)00033-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent is mounted on a balloon catheter and delivered to the site of blockage. When the balloon is inflated, the stent expands and is pressed against the inner wall of the coronary artery. After the balloon is deflated and removed, the stent remains in place. keeping the artery open. Hence, the stent expansion defines the effectiveness of the surgical procedure: it depends on the stent geometry, it includes large displacements and deformations and material non-linearity. In this paper, the finite element method is applied (i) to understand the effects of different geometrical parameters (thickness, metal-to-artery surface ratio, longitudinal and radial cut lengths) of a typical diamond-shaped coronary stent on the device mechanical performance, (ii) to compare the response of different actual stent models when loaded by internal pressure and (iii) to collect suggestions for optimizing the device shape and performance. The stent expansion and partial recoil under balloon inflation and deflation were simulated. Results showed the influence of the geometry on the stent behavior: a stent with a low metal-to-artery surface ratio has a higher radial and longitudinal recoil, but a lower dogboning. The thickness influences the stent performance in terms of foreshortening, longitudinal recoil and dogboning. In conclusion, a finite element analysis similar to the one herewith proposed could help in designing new stents or analyzing actual stents to ensure ideal expansion and structural integrity, substituting in vitro experiments often difficult and unpractical. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 25 条
[1]  
Auricchio F., 2001, COMPUT METHOD BIOMEC, V4, P249, DOI DOI 10.1080/10255840108908007
[2]  
Barragan P, 2000, CATHETER CARDIO INTE, V50, P112, DOI 10.1002/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO
[3]  
2-X
[4]   COLLAPSE OF A PALMAZ STENT IN THE SUBCLAVIAN VEIN [J].
BJARNASON, H ;
HUNTER, DW ;
CRAIN, MR ;
FERRAL, H ;
MILTZMILLER, SE ;
WEGRYN, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1123-1124
[5]   Management of restenosis after coronary intervention [J].
Dangas, G ;
Fuster, V .
AMERICAN HEART JOURNAL, 1996, 132 (02) :428-436
[6]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[7]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[8]   Mechanical properties of metallic stents: How do these properties influence the choice of stent for specific lesions? [J].
Dyet, JF ;
Watts, WG ;
Ettles, DF ;
Nicholson, AA .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (01) :47-54
[9]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075
[10]  
Fabregues S, 1998, J BIOMECH, V31, P45, DOI 10.1016/S0021-9290(97)00098-5