Sample stacking during membrane-mediated loading in automated DNA sequencing

被引:15
作者
Guttman, A [1 ]
机构
[1] Genet BioSyst Inc, San Diego, CA 92121 USA
关键词
D O I
10.1021/ac990173a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microporous membrane-mediated loading is a novel and efficient sample injection technique for ultrathin slab gel electrophoresis-based automated DNA sequence analysis. The sequencing reaction mixture is spatted directly onto the tabs of the membrane loader, which is then inserted to close proximity of the straight edge of the separation gel, The use of a higher viscosity (>60 cSt), low ionic strength (conductivity <320 mu S) well solution with a pH of more than one unit lower that of the separation and gel buffer system makes possible efficient stacking of the DNA sequencing fragments at the interface of the gel matrix. When the injection/separation process is initiated by the application of the electric field, a high local electric potential drop is formed across the low ionic strength well solution zone, This results in very fast: migration of the DNA sequencing fragments toward the interface of the separation gel, where they stack. up against the higher conductivity sieving matrix. During this stacking process, primarily the local pH mediates the actual mobility of the buffer co-ions (borate), forming the leading and terminating zones in the well solution and separation gel, respectively.
引用
收藏
页码:3598 / 3602
页数:5
相关论文
共 15 条
[1]  
Andrews A. T., 1986, ELECTROPHORESIS
[2]   Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions [J].
Carrilho, E ;
RuizMartinez, MC ;
Berka, J ;
Smirnov, I ;
Goetzinger, W ;
Miller, AW ;
Brady, D ;
Karger, BL .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3305-3313
[3]   Membrane-mediated sample loading for automated DNA sequencing [J].
Cassel, SM ;
Guttman, A .
ELECTROPHORESIS, 1998, 19 (8-9) :1341-1346
[4]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[5]  
Chrambach A., 1985, PRACTICE QUANTITATIV
[7]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[8]  
GRIFFIN HG, 1993, DNA SEQUENCING PROTO, V23
[9]   Effect of temperature on separation efficiency in capillary gel electrophoresis [J].
Guttman, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (05) :194-198
[10]  
HOWE CJ, 1989, NUCL ACID SEQUENCING