Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing

被引:59
作者
Tubic, D
Zaccarin, A
Beaulieu, L
Pouliot, J
机构
[1] Ctr Hosp Univ Quebec, Dept Radiat Oncol, Quebec City, PQ G1R 2J6, Canada
[2] Univ Laval, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Genie Elect & Genie Informat, Comp Vis & Syst Lab, Quebec City, PQ G1K 7P4, Canada
[4] Intel Corp, Santa Clara, CA 95052 USA
[5] Univ Laval, Dept Phys, St Foy, PQ G1K 7P4, Canada
[6] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1414309
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
We present an algorithm, based on simulated annealing, for automatic seed matching and three-dimensional spatial coordinate reconstruction using either three radiographic films or three fluoroscopic images taken from different perspectives. The matching problem is defined in the framework of combinatorial optimization, which allows robust reconstruction in presence of calibration imprecision, patient movements. and isometric distortions. Furthermore, by using a global criterion to select the correct matching, we evade common problems of the three-film method and its variants in presence of noise. The algorithm has been tested on 112 clinical cases and 100 simulated implants and used clinically on more than 100 cases. Simulated implants were reconstructed with an average error of 0.21 mm. For clinical cases, comparison of the precision is performed between results obtained with this new method and results obtained using the three-film technique. Compared to the latter technique, the reconstruction precision was improved in 62% of the clinical cases. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2272 / 2279
页数:8
相关论文
共 11 条
[1]
Aarts E., 1989, Wiley-Interscience Series in Discrete Mathematics and Optimization
[2]
ALMOS HI, 1981, MED PHYS, V8, P210
[3]
RAPID, ACCURATE, 3-DIMENSIONAL LOCATION OF MULTIPLE SEEDS IN IMPLANT RADIOTHERAPY TREATMENT PLANNING [J].
ALTSCHULER, MD ;
FINDLAY, PA ;
EPPERSON, RD .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (11) :1305-1318
[4]
Source localization from axial image sets by iterative relaxation of the nearest neighbor criterion [J].
Bice, WS ;
Dubois, DF ;
Prete, JJ ;
Prestidge, BR .
MEDICAL PHYSICS, 1999, 26 (09) :1919-1924
[5]
GEOMETRIC RECONSTRUCTION OF SEED IMPLANTS USING A 3-FILM TECHNIQUE [J].
BIGGS, PJ ;
KELLEY, DM .
MEDICAL PHYSICS, 1983, 10 (05) :701-704
[6]
Brent R. P., 2002, Algorithms for Minimization without Derivatives
[7]
Automated seed localization from CT datasets of the prostate [J].
Brinkmann, DH ;
Kline, RW .
MEDICAL PHYSICS, 1998, 25 (09) :1667-1672
[8]
OPTIMIZATION BY SIMULATED ANNEALING [J].
KIRKPATRICK, S ;
GELATT, CD ;
VECCHI, MP .
SCIENCE, 1983, 220 (4598) :671-680
[9]
Matsumoto M., 1998, ACM Transactions on Modeling and Computer Simulation, V8, P3, DOI 10.1145/272991.272995
[10]
AN AUTOMATIC SEED IDENTIFICATION TECHNIQUE FOR INTERSTITIAL IMPLANTS USING 3 ISOCENTRIC RADIOGRAPHS [J].
ROSENTHAL, MS ;
NATH, R .
MEDICAL PHYSICS, 1983, 10 (04) :475-479