Confluence of incident and reflected waves interferes with systolic foot detection of the carotid artery distension waveform

被引:41
作者
Hermeling, Evelien [1 ]
Reesink, Koen D. [1 ]
Reneman, Robert S. [2 ]
Hoeks, Arnold P. G. [1 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Biophys, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Physiol, NL-6200 MD Maastricht, Netherlands
关键词
blood pressure; carotid artery; pulse wave velocity; systolic foot; transit time; ultrasound; wave analysis; wave reflection;
D O I
10.1097/HJH.0b013e328311cdd5
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives Local pulse wave velocity, a direct measure of arterial stiffness, can be measured using the systolic foot of the pressure waveform as the time reference point. The accuracy and precision of systolic foot identification, which may be disturbed by early wave reflections, heavily affects pulse wave transit time measurements. We investigated within subjects the existence of early wave reflections and their interference with systolic foot identification. Methods Fourteen ultrasound-derived distension waveforms, spaced over 16.4mm, were simultaneously recorded in the CCA 3cm proximal of the bifurcation of 12 young subjects. The second derivatives of the distension waveforms were calculated to identify the systolic foot and an inflection point preceding systolic peak distension. Pulse wave transit time was calculated as the time difference between the most proximal and most distal time-point, using either the systolic foot or the inflection point. The time to reflection (Delta T-SF_(IP_)) was defined as the time difference between the systolic foot and the inflection point. Results Both transit times (TTSF and TTIP) could be determined with good intrasubject precision: 0.7 and 1.4 ms, respectively. The systolic foot is running forward, TTSF=3.1 +/- 0.9 ms, whereas the inflection point appears to run backward, TTIP=-3.9 +/- 1.4 ms. Delta T-SF_(IP) was 44.3 +/- 8.8 ms. Conclusion Despite the good intrasubject reproducibility, confluence of incident and reflected waves disturbs identification and discrimination of the systolic foot and the inflection point, resulting in biased estimates. Therefore both points are unsuitable for local pulse transit time measurements in the common carotid artery. J Hypertens 26: 2374-2380 (C) 2008 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:2374 / 2380
页数:7
相关论文
共 30 条
[1]   Wave intensity analysis from the common carotid artery: a new noninvasive index of cerebral vasomotor tone [J].
Bleasdale, RA ;
Mumford, CE ;
Campbell, RI ;
Fraser, AG ;
Jones, CJH ;
Frenneaux, MP .
HEART AND VESSELS, 2003, 18 (04) :202-206
[2]   A radio frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound [J].
Brands, PJ ;
Hoeks, APG ;
Ledoux, LAF ;
Reneman, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :911-920
[3]   A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound [J].
Brands, PJ ;
Willigers, JM ;
Ledoux, LAF ;
Reneman, RS ;
Hoeks, APG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1325-1335
[4]   Arterial pulse wave velocity with tissue Doppler imaging [J].
Eriksson, A ;
Greiff, E ;
Loupas, T ;
Persson, M ;
Pesque, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (05) :571-580
[5]   Measurement of local pulse wave velocity: Effects of signal processing on precision [J].
Hermeling, Evelien ;
Reesink, Koen D. ;
Reneman, Robert S. ;
Hoeks, Arnold P. G. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (05) :774-781
[6]  
HISTAND MB, 1973, CIRC RES, V33, P524
[7]   Non-invasive measurement of mechanical properties of arteries in health and disease [J].
Hoeks, APG ;
Brands, PJ ;
Willigers, JM ;
Reneman, RS .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H3) :195-202
[8]   Effects of assessment and processing techniques on the shape of arterial pressure-distension loops [J].
Hoeks, APG ;
Willigers, JM ;
Reneman, RS .
JOURNAL OF VASCULAR RESEARCH, 2000, 37 (06) :494-500
[9]   ASSESSMENT OF THE DISTENSIBILITY OF SUPERFICIAL ARTERIES [J].
HOEKS, APG ;
BRANDS, PJ ;
SMEETS, FAM ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (02) :121-128
[10]   COMPARISON OF THE PERFORMANCE OF THE RF CROSS-CORRELATION AND DOPPLER AUTOCORRELATION TECHNIQUE TO ESTIMATE THE MEAN VELOCITY OF SIMULATED ULTRASOUND SIGNALS [J].
HOEKS, APG ;
ARTS, TGJ ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :727-740