Small aortic annulus: The hydrodynamic performances of 5 commercially available tissue valves

被引:75
作者
Gerosa, G
Tarzia, V
Rizzoli, G
Bottio, T
机构
[1] Univ Brescia, Cardiovasc Inst, I-25100 Brescia, Italy
[2] Univ Padua, Cardiovasc Inst, Padua, Italy
关键词
D O I
10.1016/j.jtcvs.2005.12.034
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: In vivo comparison of the performance of heart valve prostheses is confounded by several factors, such as different nominal size, patients' characteristics and hemodynamics, surgical techniques, and study design. The aim of this study was to compare the in vitro hydrodynamic performances of 5 different tissue valves that would fit a 21-mm-diameter valve holder of the Sheffield pulse duplicator. Methods: Three samples of 5 supra-annular production-quality tissue valves, including the sewing ring cuffs, were tested in the aortic chamber of the Sheffield pulse duplicator. The prostheses fitting a 21-mm valve holder, which is comparable with a 21-mm aortic annulus, were as follows: 20-mm Sorin Soprano, 21-mm Carpentier-Edwards Magna, 21-mm SJM-Biocor-Epic-Supra, 21-mm Medtronic Mosaic, and 23-mm Mitroflow. The tests were carried out at a fixed pulse rate (70 beats/min) and at increasing cardiac outputs of 2, 4, 5, and 7 L/min. Each valve was tested 10 times for each different cardiac output. This resulted in a total of 40 tests for each valve and 120 tests for each valve model. Forward flow pressure decrease, effective orifice area, stroke work loss, and total regurgitant, closing, and leakage volumes were recorded while the valve operated under each cardiac output. Results: Pericardial valves showed significantly lower transvalvular gradients than porcine valves, unlike the SJM-Biocor-Epic-Supra valve at 2 L/min of cardiac output. Although the Carpentier-Edwards Magna valve provided the best performance at 2 and 4 L/min, the Mitroflow valve exhibited the lowest mean and peak gradients at 5 to 7 L/min. Total regurgitant and leakage volumes were higher for the Carpentier-Edwards Magna valve and lower for the SJM-Biocor-Epic-Supra and Mitroflow valves. Between 2 and 4 L/min, the calculated effective orifice area and stroke work loss were better for the Carpentier-Edwards Magna valve, whereas between 5 and 7 L/min, they were significantly superior with the Mitroflow prosthesis. Among the porcine bioprostheses, the SJM-Biocor-Epic-Supra valve showed significantly better results when compared with the Medtronic Mosaic valve at each cardiac output. Conclusion: Assuming that the valve holder is comparable with a defined aortic annulus of 21 mm in which a spread of supra-annular tissue valves could be fitted, this hydrodynamic evaluation model allows comparison of the efficiency of currently available bioprostheses with a definite tissue annulus diameter. Pericardial valves exhibited the best performances, and the Mitroflow valve showed the lowest gradients and stroke work loss at increasing cardiac output.
引用
收藏
页码:1058 / U29
页数:9
相关论文
共 23 条
[1]
Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves [J].
Bottio, T ;
Caprili, L ;
Casarotto, D ;
Gerosa, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (03) :457-462
[2]
Hemodynamic comparison of Bioprostheses for complete supra-annular position in patients with small aortic annulus [J].
Botzenhardt, F ;
Eichinger, WB ;
Bleiziffer, S ;
Guenzinger, R ;
Wagner, IM ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :2054-2060
[3]
Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly [J].
Carrier, M ;
Pellerin, M ;
Perrault, LP ;
Hébert, Y ;
Pagé, P ;
Cartier, R ;
Dyrda, I ;
Pelletier, LC .
ANNALS OF THORACIC SURGERY, 2001, 71 (05) :S249-S252
[4]
ECHOCARDIOGRAPHIC DESCRIPTION OF THE CARBOMEDICS BILEAFLET PROSTHETIC HEART-VALVE [J].
CHAMBERS, J ;
CROSS, J ;
DEVERALL, P ;
SOWTON, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) :398-405
[5]
Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equivalence [J].
Chambers, JB ;
Oo, L ;
Narracott, A ;
Lawford, PM ;
Blauth, CI .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) :1388-1393
[6]
Exercise hemodynamics of bovine versus porcine bioprostheses: A prospective randomized comparison of the Mosaic and Perimount aortic valves [J].
Eichinger, WB ;
Botzenhardt, F ;
Keithahn, A ;
Guenzinger, R ;
Bleiziffer, S ;
Wagner, I ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (05) :1056-1063
[8]
*INT ORG STAND, 1996, PUBL INT ORG STAND, V5840
[9]
Impact of prosthesis - Patient size on functional recovery after aortic valve replacement [J].
Koch, CG ;
Khandwala, F ;
Estafanous, FG ;
Loop, FD ;
Blackstone, EH .
CIRCULATION, 2005, 111 (24) :3221-3229
[10]
Characteristic resistance curves of aortic valve substitutes facilitate individualized decision for a particular type [J].
Kuehnel, RU ;
Puchner, R ;
Pohl, A ;
Wendt, MO ;
Hartrumpf, M ;
Pohl, M ;
Albes, JM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (03) :450-455