Hemodynamic comparison of Bioprostheses for complete supra-annular position in patients with small aortic annulus

被引:81
作者
Botzenhardt, F [1 ]
Eichinger, WB [1 ]
Bleiziffer, S [1 ]
Guenzinger, R [1 ]
Wagner, IM [1 ]
Bauernschmitt, R [1 ]
Lange, R [1 ]
机构
[1] German Heart Ctr Munich, Dept Cardiovasc Surg, Munich, Germany
关键词
D O I
10.1016/j.jacc.2005.03.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The present study evaluates complete supra-annular bioprostheses in patients with an aortic annulus of 18 to 23 mm in diameter. BACKGROUND Aortic valve replacement in patients with small aortic annulus using stented bioprostheses is often associated with unsatisfactory hemodynamic results and high incidence of patient-prosthesis mismatch. METHODS Between February 2000 and January 2004, 156 patients with aortic valve disease and an aortic annulus of 18 to 23 mm in diameter received the stented bovine Soprano (Sorin Biomedica Cardio, Saluggia, Italy) (n = 18), Perimount (Edwards Lifesciences, Irvine, California) (n = 52), Perimount Magna (Edwards Lifesciences) (n = 42), or the stented porcine Mosaic (Medtronic Inc., Minneapolis, Minnesota) (n = 44) bioprostheses. Intraoperatively, the surgeon measured the aortic annulus diameter by inserting a hegar dilator. Thus, postoperative hemodynamic results could be referred to the patient's aortic annulus diameter instead of referring the results to the labeled valve size. This allows for objective comparisons between different valve types. RESULTS There was no significant difference in hemodynamic results between the different valve types in patients with an aortic annulus 18 to 20 mm. In patients with an annulus 21 to 23 mm, the Magna was significantly superior to the other investigated devices in mean pressure gradient, effective orifice area, and incidence of patient-prosthesis mismatch. There was no significant difference between the complete supra-annular bioprostheses Mosaic and Soprano and the intra-supra-annular Perimount valve. CONCLUSIONS In patients with an aortic annulus of 18 to 20 mm in diameter, hemodynamic performance is independent of the implanted stented valve type and the annular position. Root enlargement or stentless valves may be beneficial alternatives. Patients with annulus diameter 21 to 23 mm benefit from the Magna in complete supra-annular position leading to superior hemodynamic results. (c) 2005 by the American College of Cardiology Foundation.
引用
收藏
页码:2054 / 2060
页数:7
相关论文
共 28 条
[1]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[2]   ACC/AHA guidelines for the management of patients with valvular heart disease - A report of the American College of Cardiology American Heart Association Task Force on practice guidelines (Committee on Management of Patients with Valvular Heart Disease) [J].
Bonow, RO ;
Carabello, B ;
De Leon, AC ;
Edmunds, LH ;
Fedderly, BJ ;
Freed, MD ;
Gaasch, WH ;
Mckay, CR ;
Nishimura, RA ;
O'Gara, PT ;
O'Rourke, RA ;
Rahimtoola, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1486-1582
[3]   Routine enlargement of the small aortic root: A preventive strategy to minimize mismatch [J].
Castro, LJ ;
Arcidi, JM ;
Fisher, AL ;
Gaudiani, VA .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :31-36
[4]   Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis [J].
Dellgren, G ;
David, TE ;
Raanani, E ;
Armstrong, S ;
Ivanov, J ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) :146-154
[5]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[6]   VALVE PROSTHESIS HEMODYNAMICS AND THE PROBLEM OF HIGH TRANSPROSTHETIC PRESSURE-GRADIENTS [J].
DUMESNIL, JG ;
YOGANATHAN, AP .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 :S34-S38
[7]  
Eichinger WB, 2004, J HEART VALVE DIS, V13, P382
[8]  
Eichinger WB, 2002, J HEART VALVE DIS, V11, P529
[9]   European experience with the Mosaic bioprosthesis [J].
Eichinger, WB ;
Botzenhardt, F ;
Gunzinger, R ;
Kemkes, BM ;
Sosnowski, A ;
Maïza, D ;
Coto, EO ;
Bleese, N .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) :333-339
[10]   Pericarbon pericardial bioprosthesis: An experience based on the lessons of the past [J].
Folliguet, TA ;
Le Bret, E ;
Bachet, J ;
Laborde, F .
ANNALS OF THORACIC SURGERY, 2001, 71 (05) :S289-S292