Immobilization of acetylcholinesterase and choline oxidase in/on pHEMA membrane for biosensor construction

被引:21
作者
Kok, FN
Bozoglu, F
Hasirci, V [1 ]
机构
[1] Middle E Tech Univ, Dept Sci Biol, Biotechnol Res Unit, TR-06531 Ankara, Turkey
[2] Middle E Tech Univ, Dept Biotechnol, Biotechnol Res Unit, TR-06531 Ankara, Turkey
[3] Middle E Tech Univ, Dept Food Engn, TR-06531 Ankara, Turkey
关键词
enzyme biosensor; acetylcholinesterase; pHEMA; immobilization;
D O I
10.1163/156856201753395725
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, acetylcholinesterase (AChE) and choline oxidase (ChO) were co-immobilized on poly(2-hydroxyethyl methacrylate) (pHEMA) membranes with the aim of using them in biosensor construction. pHEMA membranes were prepared with the addition of different salts in different HEMA : aqueous solution ratios and characterized in terms of porosity, thickness, permeability, and mechanical properties. Membranes prepared in the presence of SnCl4 were found to be superior in terms of porosity and permeability and were chosen as the immobilization matrix. Immobilization of the enzymes was achieved both by entrapment and surface attachment via epichlorohydrin (Epi) and Cibacron Blue F36A (CB) activation. The effect of immobilization on enzyme activity was evaluated by the comparison of K-m and V-max values for the free and immobilized bi-enzyme systems. The increase in K-m was negligible (1.08-fold) for the bi-enzyme system upon immobilization on surface but was 2.12-fold upon entrapment. Specific activity of the free enzyme system was found to be 0,306 mV s(-1) mug(-1) ChO while it was 0.069 (4.43-fold decrease) for entrapped and 0.198 (1.54 fold decrease) for CB-Epi immobilized enzymes. The performance of immobilized enzymes in different buffer types, pH, and temperature conditions were evaluated. The best enzyme activity was obtained at pH 9.0. Activity of the enzymes was found to increase with increasing temperature (in the range 25-40degreesC).
引用
收藏
页码:1161 / 1176
页数:16
相关论文
共 33 条
[1]   BIOREACTOR APPLICATIONS OF GLUCOSE-OXIDASE COVALENTLY BONDED ON PHEMA MEMBRANES [J].
ARICA, MY ;
HASIRCI, V .
BIOMATERIALS, 1993, 14 (11) :803-808
[2]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLY(2-HYDROXYETHYL METHACRYLATE) MEMBRANES [J].
ARICA, Y ;
HASIRCI, VN .
BIOMATERIALS, 1987, 8 (06) :489-495
[3]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[4]  
BOYER PM, 1993, ADV BIOCH ENG BIOTEC, V49
[5]   DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING [J].
CAGNINI, A ;
PALCHETTI, I ;
LIONTI, I ;
MASCINI, M ;
TURNER, APF .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :85-89
[6]   A new organic phase enzyme electrode for the analysis of organophosphorus pesticides and carbamates [J].
Campanella, L ;
De Luca, S ;
Sammartino, MP ;
Tomassetti, M .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :59-71
[7]   EVALUATION OF THE USE OF FREE AND IMMOBILIZED ACETYLCHOLINESTERASE FOR PARAOXON DETECTION WITH AN AMPEROMETRIC CHOLINE OXIDASE BASED BIOSENSOR [J].
CREMISINI, C ;
DISARIO, S ;
MELA, J ;
PILLOTON, R ;
PALLESCHI, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :273-280
[8]   Acetylcholine biosensor involving entrapment of acetylcholinesterase and poly(ethylene glycol)-modified choline oxidase in a poly(vinyl alcohol) cryogel membrane [J].
Doretti, L ;
Ferrara, D ;
Lora, S ;
Schiavon, F ;
Veronese, FM .
ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (3-5) :279-285
[9]   Covalently immobilized enzymes on biocompatible polymers for amperometric sensor applications [J].
Doretti, L ;
Ferrara, D ;
Gattolin, P ;
Lora, S .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (04) :365-373
[10]  
EDDOWES M, 1990, BIOSENSORS PRACTICAL