Acetylcholine biosensor involving entrapment of acetylcholinesterase and poly(ethylene glycol)-modified choline oxidase in a poly(vinyl alcohol) cryogel membrane

被引:80
作者
Doretti, L
Ferrara, D
Lora, S
Schiavon, F
Veronese, FM
机构
[1] CNR, Serv Prevenz & Protez, I-35127 Padua, Italy
[2] CNR, Ist Fotochim & Radiaz Alta Energia, I-35020 Legnaro, Padova, Italy
[3] Univ Padua, Dipartimento Sci Farmaceut, I-35131 Padua, Italy
关键词
biosensor; choline sensor; acetylcholine sensor; PEG-modified choline oxidase; PVA cryogel;
D O I
10.1016/S0141-0229(00)00210-6
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A bienzymatic sensor for the determination of acetylcholine was prepared by physical coimmobilization of acetylcholinesterase and poly(ethylene glycol)-modified choline oxidase in a poly(vinyl alcohol) cryogel membrane obtained by a cyclic freezing-thawing process. The enzyme-modified polymer was applied on a platinum electrode to form an amperometric sensor, based on the electrochemical detection of enzymatically developed hydrogen peroxide. The analytical characteristics of this sensor, including calibration curves for choline and acetylcholine, pH, and temperature effects, and stability an described. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 21 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .3. A CONDUCTING SALT ELECTRODE FOR THE OXIDATION OF 4 DIFFERENT FLAVOENZYMES [J].
ALBERY, WJ ;
BARTLETT, PN ;
BYCROFT, M ;
CRASTON, DH ;
DRISCOLL, BJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 218 (1-2) :119-126
[2]   AMPEROMETRIC ENZYME ELECTRODES .1. THEORY [J].
ALBERY, WJ ;
BARTLETT, PN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :211-222
[3]   ENZYME ELECTRODE STUDIES OF GLUCOSE-OXIDASE MODIFIED WITH A REDOX MEDIATOR [J].
BARTLETT, PN ;
BRADFORD, VQ ;
WHITAKER, RG .
TALANTA, 1991, 38 (01) :57-63
[4]   Amperometric biosensor with physically immobilized glucose oxidase on a PVA cryogel membrane [J].
Doretti, L ;
Ferrara, D ;
Gattolin, P ;
Lora, S .
TALANTA, 1997, 44 (05) :859-866
[5]   AMPEROMETRIC CHOLINE SENSOR WITH ENZYME IMMOBILIZED BY GAMMA-IRRADIATION IN A BIOCOMPATIBLE MEMBRANE [J].
DORETTI, L ;
GATTOLIN, P ;
LORA, S .
ANALYTICAL LETTERS, 1994, 27 (13) :2455-2470
[6]   PEG-modified glucose oxidase immobilized on a PVA cryogel membrane for amperometric biosensor applications [J].
Doretti, L ;
Ferrara, D ;
Gattolin, P ;
Lora, S ;
Schiavon, F ;
Veronese, FM .
TALANTA, 1998, 45 (05) :891-898
[7]  
FONTANA A, 1970, PROTEIN SEQUENCE DET, P185
[8]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[9]   DETERMINATION OF FREE AMINO GROUPS IN PROTEINS BY TRINITROBENZENESULFONIC ACID [J].
HABEEB, AFS .
ANALYTICAL BIOCHEMISTRY, 1966, 14 (03) :328-&
[10]   PURIFICATION AND CHARACTERIZATION OF CHOLINE-OXIDASE FROM ARTHROBACTER-GLOBIFORMIS [J].
IKUTA, S ;
IMAMURA, S ;
MISAKI, H ;
HORIUTI, Y .
JOURNAL OF BIOCHEMISTRY, 1977, 82 (06) :1741-1749