Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5

被引:159
作者
Henriques, JPS
Remmelink, M
Baan, J
van der Schaaf, RJ
Vis, MM
Koch, KT
Scholten, EW
de Mol, BAJM
Tijssen, JGP
Piek, JJ
de Winter, RJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1016/j.amjcard.2005.10.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently, the most used left ventricular (LV) support device is intra-aortic balloon counterpulsation. The percutaneous implantable Impella Recover LP 2.5 system is a novel LV (unloading) assist device. We studied the feasibility and safety of LV support with the percutaneous implantable Impella Recover LP 2.5 system in 19 consecutive high-risk patients with percutaneous coronary intervention. Procedural success using the device and percutaneous coronary intervention was achieved in all 19 patients, who were very poor candidates for surgery. The patients were elderly (84% were > 60 years of age), 74% had previous myocardial infarction, 63% had LV ejection fractions of <= 25%, and all had LV ejection fractions of <= 40%. There were no procedural deaths and 2 device-unrelated in-hospital late deaths. Mean decrease in hemoglobin level was 0.7 +/- 0.4 mmol/L. The device did not induce or increase aortic valve regurgitation. There were no important device-related adverse events during LV support with the Impella Recover LP 2.5 system. However, these encouraging findings must be confirmed by larger studies, longer assist times, and in other patient categories. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:990 / 992
页数:3
相关论文
共 11 条
[1]   Percutaneous left ventricular assist device: "TandemHeart" for high-risk coronary intervention [J].
Aragon, J ;
Lee, MS ;
Kar, S ;
Makkar, RR .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (03) :346-352
[2]   The effect of intra-aortic balloon counterpulsation on left ventricular functional recovery early after acute myocardial infarction: a randomized experimental magnetic resonance imaging study [J].
Azevedo, CF ;
Amado, LC ;
Kraitchman, DL ;
Gerber, BL ;
Edvardsen, T ;
Osman, NF ;
Rochitte, CE ;
Wu, KC ;
Lima, JAC .
EUROPEAN HEART JOURNAL, 2005, 26 (12) :1235-1241
[3]   Elective versus provisional intra-aortic balloon pumping in high-risk percutaneous transluminal coronary angioplasty [J].
Briguori, C ;
Sarais, C ;
Pagnotta, P ;
Airoldi, F ;
Liistro, F ;
Sgura, F ;
Spanos, V ;
Carlino, M ;
Montorfano, M ;
Di Mario, C ;
Colombo, A .
AMERICAN HEART JOURNAL, 2003, 145 (04) :700-707
[4]   Different applications for left ventricular mechanical support with the Impella Recover 100 microaxial blood pump [J].
Garatti, A ;
Colombo, T ;
Russo, C ;
Lanfranconi, M ;
Milazzo, F ;
Catena, E ;
Bruschi, G ;
Frigerio, M ;
Vitali, E .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (04) :481-485
[5]  
Meyns B, 2003, THORAC CARDIOV SURG, V51, P312
[6]   The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure:: A three-center experience [J].
Siegenthaler, MP ;
Brehm, K ;
Strecker, T ;
Hanke, T ;
Nötzold, A ;
Olschewski, M ;
Weyand, M ;
Sievers, H ;
Beyersdorf, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (03) :812-822
[7]   A prospective, randomized evaluation of prophylactic intraaortic balloon counterpulsation in high risk patients with acute myocardial infarction treated with primary angioplasty [J].
Stone, GW ;
Marsalese, D ;
Brodie, BR ;
Griffin, JJ ;
Donohue, B ;
Costantini, C ;
Balestrini, C ;
Wharton, T ;
Esente, P ;
Spain, M ;
Moses, J ;
Nobuyoshi, M ;
Ayres, M ;
Jones, D ;
Mason, D ;
Grines, L ;
ONeill, WW ;
Grines, CL ;
Sachs, D ;
Graham, M ;
McKinney, P ;
Jewett, H ;
Kreis, A ;
Brodsky, M ;
Friedman, H ;
Gangadharan, V ;
Goldman, L ;
Levin, R ;
Pavlides, G ;
Ramos, R ;
Safian, R ;
Savas, V ;
Schreiber, T ;
Ajluni, S ;
Almany, S ;
Boatman, J ;
StGoar, FG ;
Bavor, C ;
Constantino, R ;
Klughaupt, M ;
Saah, I ;
Bough, E ;
Osterle, S ;
McWard, C ;
Stuckey, TD ;
Weintraub, RA ;
Gregory, T ;
Bondy, DR ;
Lasorda, DM ;
Begg, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) :1459-1467
[8]  
Strecker T, 2004, J CARDIOVASC SURG, V45, P381
[9]   Randomized comparison of intra-aortic balloon support with a percutaneous left ventricutar assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock [J].
Thiele, H ;
Sick, P ;
Boudriot, E ;
Diederich, KW ;
Hambrecht, R ;
Niebauer, J ;
Schuler, G .
EUROPEAN HEART JOURNAL, 2005, 26 (13) :1276-1283
[10]   Left ventricular unloading and concomitant total cardiac output increase by the use of percutaneous impella recover LP 2.5 assist device during high-risk coronary intervention [J].
Valgimigli, M ;
Steendijk, P ;
Sianos, G ;
Onderwater, E ;
Serruys, PW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) :263-267