Different applications for left ventricular mechanical support with the Impella Recover 100 microaxial blood pump

被引:32
作者
Garatti, A
Colombo, T
Russo, C
Lanfranconi, M
Milazzo, F
Catena, E
Bruschi, G
Frigerio, M
Vitali, E
机构
[1] Niguarda C Granda Hosp, A De Gasperis Cardiac Surg Div, Cardiac Surg Div, I-20162 Milan, Italy
[2] Niguarda C Granda Hosp, A De Gasperis Cardiac Surg Div, Anaethesiol Div 3, I-20162 Milan, Italy
[3] Niguarda C Granda Hosp, A De Gasperis Cardiac Surg Div, Cardiac Transplant Unit, I-20162 Milan, Italy
关键词
D O I
10.1016/j.healun.2004.02.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The "Impella Recover 100" (IR100) is a new intravascular microaxial blood pump for use as short-term mechanical support for cases of acutely reduced left ventricular function. From September 2002 to April 2003, we used the IR100 to support 5 patients: 2 patients were bridged to heart transplant; 2 were being treated for fulminant acute myocarditis; and 1 for post-cardiotomy low-output syndrome. Only 1 patient with myocarditis died of septic shock, 2 had successful heart transplants; and the latter 2 were slowly weaned from the device and, at 3-month follow-up, showed moderate improvement of left ventricular (LV) function. Our initial experience with the IR100 as mechanical support for patients in cardiogenic shock of varying etiology has been positive, yielding good survival in a population of particularly compromised patients. Copyright (c) 2005 by the International Society for Heart and Lung Transplantation.
引用
收藏
页码:481 / 485
页数:5
相关论文
共 10 条
[1]  
Catena Emanuele, 2003, Ital Heart J Suppl, V4, P428
[2]  
Colombo Tiziano, 2003, Ital Heart J, V4, P642
[3]   Time course of cytokine release and complement activation after implantation of the HeartMate left ventricular assist device [J].
Corry, DC ;
DeLucia, A ;
Zhu, H ;
Radcliffe, RR ;
Brevetti, GR ;
El-Khatib, H ;
Vance, SJ ;
Moyer, BR ;
Cotts, WG ;
Richenbacher, WE .
ASAIO JOURNAL, 1998, 44 (05) :M347-M351
[4]   INTERLEUKIN-6 AND INTERLEUKIN-8 CONCENTRATIONS AS PREDICTORS OF OUTCOME IN VENTRICULAR ASSIST DEVICE PATIENTS BEFORE HEART-TRANSPLANTATION [J].
HUMMEL, M ;
CZERLINSKI, S ;
FRIEDEL, N ;
LIEBENTHAL, C ;
HASPER, D ;
VONBAEHR, R ;
HETZER, R ;
VOLK, HD .
CRITICAL CARE MEDICINE, 1994, 22 (03) :448-454
[5]   Organ perfusion with hemopump device assistance with and without intraaortic balloon pumping [J].
Meyns, B ;
Nishimura, Y ;
Racz, R ;
Jashari, R ;
Flameng, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (02) :243-253
[6]   Left ventricular support by catheter-mounted axial flow pump reduces infarct size [J].
Meyns, B ;
Stolinski, J ;
Leunens, V ;
Verbeken, E ;
Flameng, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (07) :1087-1095
[7]   Coronary artery bypass grafting supported with intracardiac microaxial pumps versus normothermic cardiopulmonary bypass:: a prospective randomized trial [J].
Meyns, B ;
Autschbach, R ;
Böning, A ;
Konertz, W ;
Matschke, K ;
Schöndube, F ;
Wiebe, K ;
Fischer, E .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (01) :112-117
[8]   The heart-pump interaction: Effects of a microaxial blood pump [J].
Stolinski, J ;
Rosenbaum, C ;
Flameng, W ;
Meyns, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (11) :1082-1088
[9]   Inflammatory response to cardiopulmonary bypass - Mechanisms involved and possible therapeutic strategies [J].
Wan, S ;
LeClerc, JL ;
Vincent, JL .
CHEST, 1997, 112 (03) :676-692
[10]   Indications and patient selection for mechanical ventricular assistance [J].
Williams, MR ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S86-S91