k-space detection and correction of physiological artifacts in fMRI

被引:65
作者
Wowk, B
McIntyre, MC
Saunders, JK
机构
[1] UNIV MANITOBA,DEPT PHYS,WINNIPEG,MB R3T 2N2,CANADA
[2] UNIV WINNIPEG,WINNIPEG,MB R3B 2E9,CANADA
关键词
fMRI; physiological correction; motion artifacts; phase correction;
D O I
10.1002/mrm.1910380625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Signal phase variations caused by physiology are a major source of instability in fMRI images produced by multiple RF pulses, k-Space phase variation maps show cyclic phase variations at the frequency of respiration combined with a cardiac variation of lower amplitude, The amplitude of the variation increases with gradient echo time and proximity to the chest, suggesting that the dominant cause of the phase variation is a B-0 shift (similar to 0.01 ppm) produced by movement of organs in the chest. A simple k-space phase correction method is proposed and demonstrated for FLASH fMRI. The retrospective method requires no pulse sequence modification, and is more effective than navigator echo correction. Physiological noise is dramatically reduced, especially at inferior slice locations.
引用
收藏
页码:1029 / 1034
页数:6
相关论文
共 21 条
[1]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[2]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[3]   DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION [J].
FRAHM, J ;
BRUHN, H ;
MERBOLDT, KD ;
HANICKE, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :501-505
[4]   Movement-related effects in fMRI time-series [J].
Friston, KJ ;
Williams, S ;
Howard, R ;
Frackowiak, RSJ ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :346-355
[5]   MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS [J].
GLOVER, GH ;
LEE, AT .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :624-635
[6]  
HAJNAL JV, 1994, MAGNET RESON MED, V31, P282
[7]   REDUCTION OF SIGNAL FLUCTUATION IN FUNCTIONAL MRI USING NAVIGATOR ECHOES [J].
HU, XP ;
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :495-503
[8]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[9]  
Jezzard P., 1993, P SMRM 12 ANN M NEW, P1392
[10]   DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION [J].
KWONG, KK ;
BELLIVEAU, JW ;
CHESLER, DA ;
GOLDBERG, IE ;
WEISSKOFF, RM ;
PONCELET, BP ;
KENNEDY, DN ;
HOPPEL, BE ;
COHEN, MS ;
TURNER, R ;
CHENG, HM ;
BRADY, TJ ;
ROSEN, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) :5675-5679