A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords

被引:55
作者
Gulani, V
Iwamoto, GA
Jiang, H
Shimony, JS
Webb, AG
Lauterbur, PC
机构
[1] UNIV ILLINOIS, DEPT MOL & INTEGRAT PHYSIOL, URBANA, IL 61801 USA
[2] UNIV ILLINOIS, COLL MED, URBANA, IL 61801 USA
[3] UNIV ILLINOIS, DEPT ELECT & COMP ENGN, URBANA, IL 61801 USA
[4] UNIV ILLINOIS, DEPT VET BIOSCI, URBANA, IL 61801 USA
关键词
diffusion MRI; diffusion tensor; spinal cord; multiple echoes;
D O I
10.1002/mrm.1910380603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new imaging sequence for rapid determination of the apparent self-diffusion tensor of water was developed and tested on fixed excised rat spinal cords. To reduce the time required to determine the tensor, the sequence utilized a new single-shot approach with multiple spin echoes. An assumption of cylindrical symmetry in the sample was made, thus requiring the measurement of only four of the six unique elements of the tenser. This assumption was found experimentally to be valid, and the results obtained using the new sequence were found to be quantitatively the same as results obtained using a standard spin-echo sequence.
引用
收藏
页码:868 / 873
页数:6
相关论文
共 34 条
  • [1] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [2] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI 10.1016/j.jmr.2011.09.022
  • [3] Changes in water diffusion due to wallerian degeneration in peripheral nerve
    Beaulieu, C
    Does, MD
    Snyder, RE
    Allen, PS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 627 - 631
  • [4] Borisenko A. I., 1966, Vector and tensor analysis with applications
  • [5] Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results
    Conturo, TE
    McKinstry, RC
    Akbudak, E
    Robinson, BH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) : 399 - 412
  • [6] Diffusion MRI: Precision, accuracy and flow effects
    Conturo, TE
    McKinstry, RC
    Aronovitz, JA
    Neil, JJ
    [J]. NMR IN BIOMEDICINE, 1995, 8 (7-8) : 307 - 332
  • [7] A METHOD FOR MYELIN FIBER ORIENTATION MAPPING USING DIFFUSION-WEIGHTED MR-IMAGES
    COREMANS, J
    LUYPAERT, R
    VERHELLE, F
    STADNIK, T
    OSTEAUX, M
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 443 - 454
  • [8] Crank J., 1975, The Mathematics of Diffusion, V2nd ed.
  • [9] ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING
    CRAWLEY, AP
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) : 34 - 47
  • [10] MR COLOR MAPPING OF MYELIN FIBER ORIENTATION
    DOUEK, P
    TURNER, R
    PEKAR, J
    PATRONAS, N
    LEBIHAN, D