Study objective: To identify and critically review the published peer-reviewed, English-language studies investigating predictive factors of fluid responsiveness in ICU patients. Design: Studies were collected by doing a search in MEDLINE (from 1966) and scanning the reference lists of the articles. Studies were selected according to the following criteria: volume expansion performed in critically ill patients, patients classified in two groups (responders and nonresponders) according to the effects of volume expansion on stroke volume or on cardiac output, and comparison of responder and nonresponder patients' characteristics before volume expansion. Results: Twelve studies were analyzed in which the parameters tested were as follows: (1) static indicators of cardiac preload (right atrial pressure [RAP], pulmonary artery occlusion pressure [PAOP], right ventricular end-diastolic volume [RVEDV], and left ventricular end-diastolic area [LVEDA]); and (2) dynamic parameters (inspiratory decrease in RAP [ARAP], expiratory decrease in arterial systolic pressure [Deltadown], respiratory changes in pulse pressure [DeltaPP], and respiratory changes in aortic blood velocity [DeltaVpeak]). Before fluid infusion, RAP, PAOP, RVEDV, and LVEDA were not significantly lower in responders than in nonresponders in three of five studies, in seven of nine studies, in four of six studies, and in one of three studies, respectively. When a significant difference was found, no threshold value could discriminate responders and nonresponders. Before fluid infusion, DeltaRAP, Deltadown, DeltaPP, and DeltaVpeak were significantly higher in responders, and a threshold value predicted fluid responsiveness with high positive (77 to 95%) and negative (81 to 100%) predictive values. Conclusion: Dynamic parameters should be used preferentially to static parameters to predict fluid responsiveness in ICU patients.
引用
收藏
页码:2000 / 2008
页数:9
相关论文
共 36 条
  • [1] BAEK SM, 1975, SURGERY, V78, P304
  • [2] RETRACTED: Volume replacement strategies on intensive care units: results from a postal survey (Retracted Article)
    Boldt, J
    Lenz, M
    Kumle, B
    Papsdorf, M
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (02) : 147 - 151
  • [3] CALVIN JE, 1981, SURGERY, V90, P61
  • [4] Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans
    Chemla, D
    Hébert, JL
    Coirault, C
    Zamani, K
    Suard, I
    Colin, P
    Lecarpentier, Y
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02): : H500 - H505
  • [5] ECHOCARDIOGRAPHIC AND HEMODYNAMIC INDEXES OF LEFT-VENTRICULAR PRELOAD IN PATIENTS WITH NORMAL AND ABNORMAL VENTRICULAR-FUNCTION
    CHEUNG, AT
    SAVINO, JS
    WEISS, SJ
    AUKBURG, SJ
    BERLIN, JA
    [J]. ANESTHESIOLOGY, 1994, 81 (02) : 376 - 387
  • [6] CORIAT P, 1994, ANESTH ANALG, V78, P46
  • [7] Determinants of aortic pressure variation during positive-pressure ventilation in man
    Denault, AY
    Gasior, TA
    Gorcsan, J
    Mandarino, WA
    Deneault, LG
    Pinsky, MR
    [J]. CHEST, 1999, 116 (01) : 176 - 186
  • [8] END-DIASTOLIC VOLUME VERSUS PULMONARY-ARTERY WEDGE PRESSURE IN EVALUATING CARDIAC PRELOAD IN TRAUMA PATIENTS
    DIEBEL, L
    WILSON, RF
    HEINS, J
    LARKY, H
    WARSOW, K
    WILSON, S
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (06) : 950 - 955
  • [9] DIEBEL LN, 1992, ARCH SURG-CHICAGO, V127, P817
  • [10] Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    Feissel, M
    Michard, F
    Mangin, I
    Ruyer, O
    Faller, JP
    Teboul, JL
    [J]. CHEST, 2001, 119 (03) : 867 - 873