Predicting fluid responsiveness in ICU patients - A critical analysis of the evidence

被引:850
作者
Michard, F [1 ]
Teboul, JL [1 ]
机构
[1] Univ Paris 11, CHU Bicetre, Serv Reanimat Med, Med ICU,Assistance Publ Hop Paris, F-94275 Le Kremlin Bicetre, France
关键词
arterial pressure; cardiac output; cardiac preload; fluid responsiveness; left ventricular end-diastolic area; pulmonary artery occlusion pressure; right atrial pressure; right ventricular end-diastolic volume; stroke volume; volume expansion;
D O I
10.1378/chest.121.6.2000
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To identify and critically review the published peer-reviewed, English-language studies investigating predictive factors of fluid responsiveness in ICU patients. Design: Studies were collected by doing a search in MEDLINE (from 1966) and scanning the reference lists of the articles. Studies were selected according to the following criteria: volume expansion performed in critically ill patients, patients classified in two groups (responders and nonresponders) according to the effects of volume expansion on stroke volume or on cardiac output, and comparison of responder and nonresponder patients' characteristics before volume expansion. Results: Twelve studies were analyzed in which the parameters tested were as follows: (1) static indicators of cardiac preload (right atrial pressure [RAP], pulmonary artery occlusion pressure [PAOP], right ventricular end-diastolic volume [RVEDV], and left ventricular end-diastolic area [LVEDA]); and (2) dynamic parameters (inspiratory decrease in RAP [ARAP], expiratory decrease in arterial systolic pressure [Deltadown], respiratory changes in pulse pressure [DeltaPP], and respiratory changes in aortic blood velocity [DeltaVpeak]). Before fluid infusion, RAP, PAOP, RVEDV, and LVEDA were not significantly lower in responders than in nonresponders in three of five studies, in seven of nine studies, in four of six studies, and in one of three studies, respectively. When a significant difference was found, no threshold value could discriminate responders and nonresponders. Before fluid infusion, DeltaRAP, Deltadown, DeltaPP, and DeltaVpeak were significantly higher in responders, and a threshold value predicted fluid responsiveness with high positive (77 to 95%) and negative (81 to 100%) predictive values. Conclusion: Dynamic parameters should be used preferentially to static parameters to predict fluid responsiveness in ICU patients.
引用
收藏
页码:2000 / 2008
页数:9
相关论文
共 36 条
[31]   The use of transesophageal echocardiography for preload assessment in critically ill patients [J].
Tousignant, CP ;
Walsh, F ;
Mazer, CD .
ANESTHESIA AND ANALGESIA, 2000, 90 (02) :351-355
[32]   COMPARISON OF TRANSESOPHAGEAL ECHOCARDIOGRAPHIC AND SCINTIGRAPHIC ESTIMATES OF LEFT-VENTRICULAR END-DIASTOLIC VOLUME INDEX AND EJECTION FRACTION IN PATIENTS FOLLOWING CORONARY-ARTERY BYPASS-GRAFTING [J].
URBANOWICZ, JH ;
SHAABAN, MJ ;
COHEN, NH ;
CAHALAN, MK ;
BOTVINICK, EH ;
CHATTERJEE, K ;
SCHILLER, NB ;
DAE, MW ;
MATTHAY, MA .
ANESTHESIOLOGY, 1990, 72 (04) :607-612
[33]   Hemodynamic support in septic shock [J].
Vincent, JL .
INTENSIVE CARE MEDICINE, 2001, 27 (Suppl 1) :S80-S92
[34]   Right ventricular end-diastolic volume as a predictor of the hemodynamic response to a fluid challenge [J].
Wagner, JG ;
Leatherman, JW .
CHEST, 1998, 113 (04) :1048-1054
[35]  
[No title captured]
[36]  
[No title captured]