Reliability of fractional flow reserve measurements in patients with associated microvascular dysfunction: Importance of flow on translesional pressure gradient

被引:33
作者
Claeys, MJ [1 ]
Bosmans, JM [1 ]
Hendrix, J [1 ]
Vrints, CJ [1 ]
机构
[1] Univ Antwerp Hosp, Div Cardiol, B-2650 Edegem, Belgium
关键词
fractional flow reserve; microvascular dysfunction; infarction; ischemia;
D O I
10.1002/ccd.2005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fractional flow reserve (FFR) has been applied with success as a lesion-specific functional indicator of stenosis severity, at least in patients with normal microcirculation. This study sought to assess the reliability of FFR calculations in patients with associated microvascular dysfunction (e.g., post myocardial infarction, or post-MI). First, the effect of coronary flow changes on translesional pressure gradient was assessed. Therefore, intracoronary pressure and flow was recorded simultaneously across 19 non-infarct-related lesions (both pre- and postinterventional lesions with a mean diameter stenosis of 47% +/- 12%). Measurements were performed by means of a pressure and Doppler wire during maximal hyperemia and also during submaximal hyperemia induced by low-dose adenosine. The drop of coronary flow from 48 +/- 23 ml/min during maximal hyperemia to 36 +/- 18 ml/min during submaximal hyperemia was associated with a small decrease in translesional pressure gradient (from 22 +/- 12 mm Hg to 19 +/- 12 mm Hg; P = 0.02) and a small increase in the mean distal/arterial pressure ratio (Pd/Pa) going from 77% +/- 11% to 81% +/-: 11% (P = 0.003). Then, intracoronary pressure and flow measurements were compared across 21 non-infarct-related lesions vs. 22 matched infarct-related lesions. For a similar angiographic stenosis severity (% DS = +/- 44%), maximal flow was 48 +/- 22 ml/min in the non-infarct arteries and 37 +/- 26 ml/min in the infarct arteries (P = 0.03), confirming the presence of severe microvascular dysfunction in infarct regions. Similar to the earlier findings, this hyperemic flow reduction in Mi patients was associated with a small increase of FFR (= Pd/Pa): 79% +/- 12% in no MI vs. 83% +/- 12% in Mi patients (P = 0.3). A reduction of hyperemic flow by + 5%, such as can be found in patients with severely impaired microvascular function, has a limited effect on FFR calculations (+ 5%). This finding allows the application of standard FFR calculations in a more general population of ischemic heart disease, including patients with recent (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:427 / 434
页数:8
相关论文
共 20 条
[1]   Improved assessment of coronary stenosis severity using the relative flow velocity reserve [J].
Baumgart, D ;
Haude, M ;
Goerge, G ;
Ge, JB ;
Vetter, S ;
Dagres, N ;
Heusch, G ;
Erbel, R .
CIRCULATION, 1998, 98 (01) :40-46
[2]   Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty [J].
Bech, GJW ;
Pijls, NHJ ;
De Bruyne, B ;
Peels, KH ;
Michels, HR ;
Bonnier, HJRM ;
Koolen, JJ .
CIRCULATION, 1999, 99 (07) :883-888
[3]   Coronary flow reserve during coronary angioplasty in patients with a recent myocardial infarction: Relation to stenosis and myocardial viability [J].
Claeys, MJ ;
Vrints, CJ ;
Bosmans, J ;
Krug, B ;
Blockx, PP ;
Snoeck, JP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (07) :1712-1719
[4]  
Claeys MJ, 1997, EUR J NUCL MED, V24, P1121
[5]   Simultaneous coronary pressure and flow velocity measurements in humans - Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve [J].
deBruyne, B ;
Bartunek, J ;
Sys, SU ;
Pijls, NHJ ;
Heyndrickx, GR ;
Wijns, W .
CIRCULATION, 1996, 94 (08) :1842-1849
[6]   RELATION BETWEEN MYOCARDIAL FRACTIONAL FLOW RESERVE CALCULATED FROM CORONARY PRESSURE MEASUREMENTS AND EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA [J].
DEBRUYNE, B ;
BARTUNEK, J ;
SYS, SU ;
HEYNDRICKX, GR .
CIRCULATION, 1995, 92 (01) :39-46
[7]   Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment [J].
Hanekamp, CEE ;
Koolen, JJ ;
Pijls, NHJ ;
Michels, HR ;
Bonnier, HJRM .
CIRCULATION, 1999, 99 (08) :1015-1021
[8]   INTRACORONARY DOPPLER GUIDE-WIRE VERSUS STRESS SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC TL-201 IMAGING IN ASSESSMENT OF INTERMEDIATE CORONARY STENOSES [J].
JOYE, JD ;
SCHULMAN, DS ;
LASORDA, D ;
FARAH, T ;
DONOHUE, BC ;
REICHEK, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :940-947
[9]   CLINICAL OUTCOME OF DEFERRING ANGIOPLASTY IN PATIENTS WITH NORMAL TRANSLESIONAL PRESSURE-FLOW VELOCITY-MEASUREMENTS [J].
KERN, MJ ;
DONOHUE, TJ ;
AGUIRRE, FV ;
BACH, RG ;
CARACCIOLO, EA ;
WOLFORD, T ;
MECHEM, CJ ;
FLYNN, MS ;
CHAITMAN, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (01) :178-187
[10]   From research to clinical practice: Current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory [J].
Kern, MJ ;
deBruyne, B ;
Pijls, NHJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :613-620