Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience

被引:211
作者
Chae, Eun Jin [1 ,2 ]
Song, Jae-Woo [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Krauss, Bernhard [3 ]
Jang, Yu Mi [1 ,2 ]
Song, Koun-Sik [1 ,2 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Siemens Med Solut, Forchheim, Germany
关键词
D O I
10.1148/radiol.2492071956
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the clinical utility of dual-energy computed tomography (CT) in evaluating solitary pulmonary nodules (SPNs). Materials and Methods: This study was approved by the institutional review board, and informed consent was obtained. CT scans were obtained before and 3 minutes after contrast material injection in 49 patients (26 men, 23 women; mean age, 60.39 years +/- 12.24 [standard deviation]) by using a scanner with a dual-energy technique. Image sets that included nonenhanced weighted average, enhanced weighted average, virtual nonenhanced, and iodine-enhanced images were reconstructed. CT numbers of SPNs on virtual nonenhanced and nonenhanced weighted average images were compared, and CT numbers on iodine-enhanced image and the degree of enhancement were compared. Diagnostic accuracy for malignancy by using CT number on iodine-enhanced image and the degree of enhancement were compared. On the virtual nonenhanced image, the number and size of calcifications were compared with those on the nonenhanced weighted average image. Radiation dose was compared with that of single-energy CT. Results: CT numbers on virtual nonenhanced and nonenhanced weighted average images and CT numbers on the iodine-enhanced image and the degree of enhancement showed good agreements (intraclass correlation coefficients: 0.83 and 0.91, respectively). Diagnostic accuracy for malignancy by using CT numbers on iodine-enhanced image was comparable to that by using the degree of enhancement (sensitivity, 92% and 72%; specificity, 70% and 70%; accuracy, 82.2% and 71.1%, respectively). On virtual nonenhanced image, 85.0% (17 of 20) of calcifications in the SPN and 97.8% (44 of 45) of calcifications in the lymph nodes were detected, and the apparent sizes were smaller than those on the nonenhanced weighted average image. Radiation dose (average dose-length product, 240.77 mGy . cm) was not significantly different from that of single-energy CT (P = .67). Conclusion: Dual-energy CT allows measurement of the degree of enhancement and detection of calcifications without additional radiation dose. (c) RSNA, 2008
引用
收藏
页码:671 / 681
页数:11
相关论文
共 15 条
  • [1] QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING
    BROOKS, RA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) : 487 - 493
  • [2] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [3] Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT
    Jeong, YJ
    Lee, KS
    Jeong, SY
    Chung, MJ
    Shim, SS
    Kim, H
    Kwon, OJ
    Kim, S
    [J]. RADIOLOGY, 2005, 237 (02) : 675 - 683
  • [4] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [5] AN ALGORITHM FOR NOISE SUPPRESSION IN DUAL ENERGY CT MATERIAL DENSITY IMAGES
    KALENDER, WA
    KLOTZ, E
    KOSTARIDOU, L
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (03) : 218 - 224
  • [6] KELCZ F, 1979, Medical Physics (Woodbury), V6, P418, DOI 10.1118/1.594520
  • [7] Measurement variability and confidence intervals in medicine: Why should radiologists care?
    Medina, LS
    Zurakowski, D
    [J]. RADIOLOGY, 2003, 226 (02) : 297 - 301
  • [8] Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    Siegel, MJ
    Schmidt, B
    Bradley, D
    Suess, C
    Hildebolt, C
    [J]. RADIOLOGY, 2004, 233 (02) : 515 - 522
  • [9] SOLITARY PULMONARY NODULE - CT EVALUATION OF ENHANCEMENT WITH IODINATED CONTRAST MATERIAL - A PRELIMINARY-REPORT
    SWENSEN, SJ
    MORIN, RL
    SCHUELER, BA
    BROWN, LR
    CORTESE, DA
    PAIROLERO, PC
    BRUTINEL, WM
    [J]. RADIOLOGY, 1992, 182 (02) : 343 - 347
  • [10] Lung nodule enhancement at CT:: Multicenter study
    Swensen, SJ
    Viggiano, RW
    Midthun, DE
    Müller, NL
    Sherrick, A
    Yamashita, K
    Naidich, DP
    Patz, EF
    Hartman, TE
    Muhm, JR
    Weaver, AL
    [J]. RADIOLOGY, 2000, 214 (01) : 73 - 80