摘要
An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:944 / 950
页数:7
相关论文
共 24 条
  • [1] Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography
    Bidlingmaier, B
    Unger, KK
    von Doehren, N
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 11 - 16
  • [2] SilicaROD™ -: A new challenge in fast high-performance liquid chromatography separations
    Cabrera, K
    Wieland, G
    Lubda, D
    Nakanishi, K
    Soga, N
    Minakuchi, H
    Unger, KK
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) : 50 - 53
  • [3] Cheng YF, 2001, RAPID COMMUN MASS SP, V15, P141, DOI 10.1002/1097-0231(20010130)15:2<141::AID-RCM201>3.0.CO
  • [4] 2-I
  • [5] COX KA, 2001, AM PHARM REV, V4, P45
  • [6] Dear G, 2001, RAPID COMMUN MASS SP, V15, P152, DOI 10.1002/1097-0231(20010130)15:2<152::AID-RCM206>3.3.CO
  • [7] 2-R
  • [8] HSIEH Y, 2001, ANALYST, V27, P285
  • [9] Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry
    Hsieh, YS
    Chintala, M
    Mei, H
    Agans, J
    Brisson, JM
    Ng, K
    Korfmacher, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) : 2481 - 2487
  • [10] Hsieh YS, 2000, RAPID COMMUN MASS SP, V14, P1384, DOI 10.1002/1097-0231(20000815)14:15<1384::AID-RCM32>3.0.CO