Novel cesium-selective electrodes based on lipophilic 1,3-bisbridged cofacial-calix[6]crowns

被引:10
作者
Jeon, SW [1 ]
Yeo, HY
Lee, HK
Ko, SW
Nam, KC
机构
[1] Chonnam Natl Univ, Dept Chem, Kwangju 500757, South Korea
[2] Chonnam Natl Univ, Inst Basic Sci, Kwangju 500757, South Korea
关键词
cesium-selective electrodes; 1,3-bisbridged cofacial-calix[6]crown-4-ethers; PVC membranes; plasticizer;
D O I
10.1002/elan.200402847
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Five bisbridged calix[6]crowns have been investigated as Cs+ ionophore in PVC membrane electrodes. As ionophores, three 1,3-bisbridged calix[6]crown-4-ethers(I -III), 1,3-bisbridged calix[6]crown-5-ether(IV), and 1,3-bisbridged calix[6]crown-6-ether(V) have been evaluated. The membranes all give good Nernstian response in the concentration range from 1 x 10(-7) to 1 x 10(-1) M of cesium ion. The best detection limits (-log a(cs+) = 7.08-7.36) are obtained for electrode membranes containing 1,3-bisbridged cofacial-calix[6]crown-4-ethers(I-III), and the values are the lowest compared with those reported previously. The highest selectivity coefficients [pK(Cs+j)(pot) = 5.53(Cs/Na), 3.74(Cs/K), 2.63(Cs/Rb)] are obtained for the membrane of 1,3-bisbridged calix[6]crown-4-ether(II), and these values are also the highest compared with previous reports for Cs+-ISEs. The highest selectivity towards cesium ion is attributed to the geometrically cofacial positions of two crown-ethers in calix[6]crowns in order to provide the complex of cesium ion and eight oxygens of cofacial crowns.
引用
收藏
页码:472 / 477
页数:6
相关论文
共 23 条
[1]   DOUBLY CROWNED CALIX[4]ARENES IN THE 1,3-ALTERNATE CONFORMATION AS CESIUM-SELECTIVE CARRIERS IN SUPPORTED LIQUID MEMBRANES [J].
ASFARI, Z ;
BRESSOT, C ;
VICENS, J ;
HILL, C ;
DOZOL, JF ;
ROUQUETTE, H ;
EYMARD, S ;
LAMARE, V ;
TOURNOIS, B .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3133-3139
[2]   SELECTIVITY OF CALIX[4]ARENE CROWN-6 FOR CESIUM ION IN ISE - EFFECT OF THE CONFORMATION [J].
BOCCHI, C ;
CARERI, M ;
CASNATI, A ;
MORI, G .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4234-4238
[3]  
CADOGAN A, 1991, Analytical Proceedings, V28, P13
[4]   CESIUM-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE ELECTRODES BASED ON CALIX[6]ARENE ESTERS [J].
CADOGAN, A ;
DIAMOND, D ;
SMYTH, MR ;
SVEHLA, G ;
MCKERVEY, MA ;
SEWARD, EM ;
HARRIS, SJ .
ANALYST, 1990, 115 (09) :1207-1210
[5]   STUDY OF THE BEHAVIOR OF CALIX[4]ARENE-BASED SODIUM-SELECTIVE ELECTRODES BY MEANS OF ANOVA [J].
CARERI, M ;
CASNATI, A ;
GUARINONI, A ;
MANGIA, A ;
MORI, G ;
POCHINI, A ;
UNGARO, R .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3156-3160
[6]   Cesium selective electrodes based on novel double flexible spacers bridged biscalix[4]arenes [J].
Chen, LX ;
Ju, HF ;
Zeng, XS ;
He, XW ;
Zhang, ZZ .
ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) :41-46
[7]  
Choi EM, 2001, B KOREAN CHEM SOC, V22, P1345
[8]   HOST-GUEST COMPLEXATION .45. A HIGHLY PREORGANIZED CHROMOGENIC SPHERAND INDICATOR SYSTEM SPECIFIC FOR SODIUM AND LITHIUM IONS [J].
CRAM, DJ ;
CARMACK, RA ;
HELGESON, RC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (02) :571-577
[9]   COMPLEXATION OF ALKALI-METAL CATIONS BY CONFORMATIONALLY RIGID, STEREOISOMERIC CALIX[4]ARENE CROWN ETHERS - A QUANTITATIVE-EVALUATION OF PREORGANIZATION [J].
GHIDINI, E ;
UGOZZOLI, F ;
UNGARO, R ;
HARKEMA, S ;
ABUELFADL, A ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (19) :6979-6985
[10]   Discrimination between butylammonium isomers by calix[5]arene-based ISEs [J].
Giannetto, M ;
Mori, G ;
Notti, A ;
Pappalardo, S ;
Parisi, MF .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4631-4635