Rollback in posterior cruciate ligament-retaining total knee arthroplasty - A radiographic analysis

被引:42
作者
Kim, H [1 ]
Pelker, RR [1 ]
Gibson, DH [1 ]
Irving, JF [1 ]
Lynch, JK [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT ORTHOPAED & REHABIL,KNEE CTR,NEW HAVEN,CT 06510
关键词
total knee arthroplasty; posterior cruciate ligament-retaining; rollback; tibiofemoral angle;
D O I
10.1016/S0883-5403(97)90179-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A clinical and radiographic study of 49 posterior cruciate ligament-retaining total knee arthroplasties in 38 patients (11 bilateral, 27 unilateral), using prostheses of the same design, was undertaken to quantify the amount of in viva rollback (ie, the anteroposterior translation of the tibia with respect to the femur during flexion). The mean difference in the distances between the contact points of the knees in full extension and in 90 degrees flexion (ie, the rollback distance) was a posterior translation of the contact point of -0.2 mm (-12.7 to +7.6 mm; SD, 4.7 mm) relative to the prosthetic tibial tray, corresponding to an average translation of 0% of the prosthetic tibial tray depth, and -0.2 mm (-12.5 to +9.1 mm; SD, 4.8 mm) relative to the tibia itself, corresponding to an average translation of 0% of the true tibial surface depth. The differences between the rollback values obtained from the 90 degrees and full-extension radiographs relative to the prosthetic tibial tray (P =.63) and the true tibia (P = .89) were not statistically significant. Intraobserver (P =.27-.50) and interobserver (P =.13-.72) reliability tests showed that the differences between radiographic measurements taken by the same observer at two different points in time and by two different observers were not statistically significant. No correlations were found between the degree of translation of the tibiofemoral contact point relative to the prosthetic tibial tray and the posterior tilt of the tibial tray (R-2 =.12), the preoperative tibiofemoral angle (R-2 =.34), and the postoperative tibiofemoral angle (R-2 = .027). No correlations were found between the degree of translation of the tibiofemoral contact point relative to the true tibia and the posterior tilt of the tibial tray (R-2 =.16), the preoperative tibiofemoral angle (R-2 =.14), and the postoperative tibiofemoral angle (R-2 =.034). In conclusion, this study indicated no demonstrable rollback occurring in the posterior cruciate ligament-retaining total knee arthroplasty used in this study.
引用
收藏
页码:553 / 561
页数:9
相关论文
共 47 条
[21]   USE OF A TOTAL CONDYLAR KNEE PROSTHESIS FOR TREATMENT OF OSTEO-ARTHRITIS AND RHEUMATOID-ARTHRITIS - LONG-TERM RESULTS [J].
GOLDBERG, VM ;
FIGGIE, MP ;
FIGGIE, HE ;
HEIPLE, KG ;
SOBEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (06) :802-811
[22]   LIGAMENTOUS AND CAPSULAR RESTRAINTS PREVENTING STRAIGHT MEDIAL AND LATERAL LAXITY IN INTACT HUMAN CADAVER KNEES [J].
GROOD, ES ;
NOYES, FR ;
BUTLER, DL ;
SUNTAY, WJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (08) :1257-1269
[23]  
HORWOOD RL, 1988, T ORTHOP RES SOC, V13, P543
[24]  
INSALL J, 1979, CLIN ORTHOP RELAT R, V145, P68
[25]   THE TOTAL CONDYLAR KNEE PROSTHESIS IN GONARTHROSIS - A 5 TO 9-YEAR FOLLOW-UP OF THE 1ST 100 CONSECUTIVE REPLACEMENTS [J].
INSALL, JN ;
HOOD, RW ;
FLAWN, LB ;
SULLIVAN, DJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :619-628
[26]  
ISEKI F, 1976, Keio Journal of Medicine, V25, P37
[27]  
KAPANDJI IA, 1970, PHYSL JOINTS, P114
[28]  
KELMAN GJ, 1989, CLIN ORTHOP RELAT R, V248, P21
[29]   TENSION STUDIES OF HUMAN KNEE LIGAMENTS - YIELD-POINT, ULTIMATE FAILURE, AND DISRUPTION OF CRUCIATE AND TIBIAL COLLATERAL LIGAMENTS [J].
KENNEDY, JC ;
HAWKINS, RJ ;
WILLIS, RB ;
DANYLCHUK, KD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03) :350-355
[30]   GEOMETRY AND MOTION OF THE KNEE FOR IMPLANT AND ORTHOTIC DESIGN [J].
KUROSAWA, H ;
WALKER, PS ;
ABE, S ;
GARG, A ;
HUNTER, T .
JOURNAL OF BIOMECHANICS, 1985, 18 (07) :487-+