Field-enhanced sample injection for high-sensitivity analysis of peptides and proteins in capillary electrophoresis-mass spectrometry

被引:52
作者
Monton, MRN [1 ]
Terabe, S [1 ]
机构
[1] Himeji Inst Technol, Grad Sch Sci, Kamigori, Hyogo 6781297, Japan
关键词
field-enhanced sample stacking; peptides; proteins;
D O I
10.1016/j.chroma.2003.10.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Field-enhanced sample injection (FESI) was used to improve the concentration sensitivity of a capillary electrophoresis (CE)-mass spectrometry (MS) system with sheath flow configuration. Using some bioactive peptides, more than 3000-fold improvement in signal was obtained, permitting analysis in the low nM (fmol/mul) levels. The system was further evaluated for analysis of complex peptide mixtures by using low concentration tryptic digests of standard proteins. Rapid identification of the original protein was obtained by database searching using the observed molecular masses of the peptides, and by comparison of actual MS-MS spectra of selected peptides with the predicted fragmentation patterns. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 39 条
[1]   Analysis of histones by on-line capillary zone electrophoresis-electrospray ionisation mass spectrometry [J].
Aguilar, C ;
Hofte, AJP ;
Tjaden, UR ;
van der Greef, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :57-67
[2]   Ultrasensitive detection of closely related angiotensin I peptides doing capillary electrophoresis with near-infrared laser-induced fluorescence detection [J].
Baars, MJ ;
Patonay, G .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :667-671
[3]   Separation and determination of neuropeptides in human plasma by capillary zone electrophoresis [J].
Ban, EM ;
Kim, D ;
Yoo, EA ;
Yoo, YS .
ANALYTICAL SCIENCES, 1997, 13 :489-492
[4]   Fluorescence detection of proteins and amino acids in capillary electrophoresis using a post-column sheath flow reactor [J].
Coble, PG ;
Timperman, AT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) :309-315
[5]  
De Hoffmann E., 1996, MASS SPECTROMETRY PR
[6]  
Ding WL, 1997, HRC-J HIGH RES CHROM, V20, P575
[7]   ONLINE TIME-OF-FLIGHT MASS-SPECTROMETRIC ANALYSIS OF PEPTIDES SEPARATED BY CAPILLARY ELECTROPHORESIS [J].
FANG, LL ;
ZHANG, R ;
WILLIAMS, ER ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3696-3701
[8]   Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level [J].
Figeys, D ;
vanOostveen, I ;
Ducret, A ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1822-1828
[9]   Ultraviolet detector response of glycine and alanine homopeptides:: Some specific features in capillary electrophoresis [J].
Hamrníková, I ;
Miksík, I ;
Uhrová, M ;
Deyl, Z .
ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) :257-272
[10]   A sheathless nanoflow electrospray interface for on-line capillary electrophoresis mass spectrometry [J].
Janini, GM ;
Conrads, TP ;
Wilkens, KL ;
Issaq, HJ ;
Veenstra, TD .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1615-1619