A Simple, Robust Orthogonal Background Correction Method for Two-Dimensional Liquid Chromatography

被引:22
作者
Filgueira, Marcelo R. [1 ,2 ]
Castells, Cecilia B. [2 ]
Carr, Peter W. [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[2] Natl Univ La Plata, Fac Ciencias Exactas, Div Quim Analit, RA-1900 La Plata, Argentina
基金
美国国家科学基金会;
关键词
PEAK-CAPACITY; REMOVAL; SPECTRA;
D O I
10.1021/ac301248h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background correction is a very important step that must be performed before peak detection or any quantification procedure. When successful, this step greatly simplifies such procedures and enhances the accuracy of quantification. In the past, much effort has been invested to correct drifting baseline in one-dimensional chromatography. In fast online comprehensive two-dimensional liquid chromatography (LCxLC) coupled with a diode array detector (DAD), the change in the refractive index (RI) of the mobile phase in very fast gradients causes extremely serious baseline disturbances. The method reported here is based on the use of various existing baseline correction methods of one-dimensional (1D) liquid chromatography to correct the two-dimensional (2D) background in LCxLC. When such methods are applied orthogonally to the second dimension (D-2), background correction is dramatically improved. The method gives an almost zero mean background level and it provides better background correction than does simple subtraction of a blank. Indeed, the method proposed does not require running a blank sample.
引用
收藏
页码:6747 / 6752
页数:6
相关论文
共 20 条
[1]   Quantification in comprehensive two-dimensional gas chromatography and a model of quantification based on selected summed modulated peaks [J].
Amador-Munoz, Omar ;
Marriott, Philip J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :323-340
[2]   Factors that affect quantification of diode array data in comprehensive two-dimensional liquid chromatography using chemometric data analysis [J].
Bailey, Hope P. ;
Rutan, Sarah C. ;
Carr, Peter W. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (46) :8411-8422
[3]   Matched filtering with background suppression for improved quality of base peak chromatograms and mass spectra in liquid chromatography-mass spectrometry [J].
Danielsson, R ;
Bylund, D ;
Markides, KE .
ANALYTICA CHIMICA ACTA, 2002, 454 (02) :167-184
[4]  
Eilers P., 2005, LEIDEN U MEDICAL CTR
[5]  
Felinger A., 1998, DATA ANAL SIGNAL PRO
[6]   Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting [J].
Filgueira, Marcelo R. ;
Huang, Yuan ;
Witt, Klaus ;
Castells, Cecilia ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2011, 83 (24) :9531-9539
[7]   Chemometric strategies for enhancing the chromatographic methodologies with second-order data analysis of compounds when peaks are overlapped [J].
Goicoechea, H. C. ;
Culzoni, M. J. ;
Gil Garcia, M. D. ;
Martinez Calera, M. .
TALANTA, 2011, 83 (04) :1098-1107
[8]   Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC x LC) [J].
Gu, Haiwei ;
Huang, Yuan ;
Filgueira, Marcelo ;
Carr, Peter W. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) :6675-6687
[9]   Effects of the gradient profile, sample volume and solvent on the separation in very fast gradients, with special attention to the second-dimension gradient in comprehensive two-dimensional liquid chromatography [J].
Jandera, Pavel ;
Hajek, Tomas ;
Cesla, Petr .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (15) :1995-2006
[10]   Comparison of Several Methods of Chromatographic Baseline Removal with a New Approach Based on Quantile Regression [J].
Komsta, L. .
CHROMATOGRAPHIA, 2011, 73 (7-8) :721-731