Coupling device for desorption of drugs from solid-phase extraction-pipette tips and on-line gas chromatographic analysis

被引:27
作者
van Hout, MWJ [1 ]
de Zeeuw, RA [1 ]
de Jong, GJ [1 ]
机构
[1] Univ Groningen, Ctr Pharm, Dept Analyt Chem & Toxicol, NL-9713 AV Groningen, Netherlands
关键词
instrumentation; interfaces; solid-phase extraction-pipette tips-programmed-temperature vaporiser; programmed temperature vaporiser; injection methods; lidocaine; diazepam; benzodiazepines;
D O I
10.1016/S0021-9673(99)00806-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase extraction-pipette tips were used for micro solid-phase extraction of lidocaine and diazepam. Off-line desorption was done after in-vial collection for reference purposes, whereas with on-line desorption the eluate was directly introduced in the gas chromatograph. With both methods the total eluate (100 mu l) was introduced into the GC system, which was equipped with a programmed-temperature vaporiser (PTV) for large volume injection. For on-line desorption a laboratory-made coupling device was developed to connect the pipette tips with the injector of the PTV. The coupling device was applied successfully since no leakage occurred at the connection of the coupling device and the pipette tip. No significant differences in recovery of lidocaine and diazepam and in presence of impurities were observed between chromatograms obtained with either off-line or on-line desorption. Preliminary experiments with standard solutions showed recoveries of about 75% for a concentration level of 1 mu g/ml. The system seems particularly suitable for high-throughput analysis. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 29 条
[1]  
BLEVINS DD, 1998, SPEC NEWS, V3, P1
[2]   USE OF MEMBRANE EXTRACTION DISKS FOR ONLINE TRACE ENRICHMENT OF ORGANIC-COMPOUNDS FROM AQUEOUS SAMPLES [J].
BROUWER, ER ;
LINGEMAN, H ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1990, 29 (9-10) :415-418
[3]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS IN SURFACE-WATER USING MEMBRANE EXTRACTION DISKS FOR ONLINE TRACE ENRICHMENT [J].
BROUWER, ER ;
VANIPEREN, DJ ;
LISKA, I ;
LINGEMAN, H ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 47 (04) :257-266
[4]  
CHEN XH, 1992, FORENSIC SCI REV, V4, P147
[5]   EXTRACTION OF TRACE AMOUNTS OF ORGANIC-COMPOUNDS FROM WATER WITH POROUS ORGANIC POLYMERS [J].
DRESSLER, M .
JOURNAL OF CHROMATOGRAPHY, 1979, 165 (02) :167-206
[6]   Automated solid-phase extraction on-line coupled to gas chromatography [J].
Enoch, P ;
Putzler, A ;
Rinne, D ;
Schlüter, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (01) :75-82
[7]  
ENSING K, 1992, J FORENSIC SCI, V37, P460
[8]  
Franke JP, 1998, J CHROMATOGR B, V713, P51
[9]  
FREI RW, 1988, SELECTIVE SAMPLE H A
[10]   On-line sample treatment - Capillary gas chromatography [J].
Goosens, EC ;
de Jong, D ;
de Jong, GJ ;
Brinkman, UAT .
CHROMATOGRAPHIA, 1998, 47 (5-6) :313-345