Behavior of cation-exchange materials in capillary electrochromatography

被引:38
作者
Cikalo, MG [1 ]
Bartle, KD [1 ]
Myers, P [1 ]
机构
[1] Univ Leeds, Sch Chem, Leeds LS2 9JT, W Yorkshire, England
关键词
D O I
10.1021/ac980960s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The behavior of a strong, cation-exchange material (propanesulfonic acid, SCX) has been studied in capillary electrophoresis (CE) and capillary electrochromatography (CEC) by the use of coated and packed capillaries. In aqueous electrolytes, the SCX-coated capillary showed a far more consistent electroosmotic now over the pH range 3.6-10.5, compared to untreated fused silica, However, in similar electrolytes containing 80% (v/v) acetonitrile, both coated and untreated capillaries performed similarly, casting doubts upon the stability of the SCX coating. The effect of voltage and mobile-phase parameters such as pH, ionic strength, and organic content was studied in CEC for both 3-mu m SCX and C-18 packing materials, and the results were compared in terms of linear velocities, currents, and conductivities. Only at pH 5 and below was a higher EOF velocity than expected observed for the SCX column. In accordance with theory, the EOF was seen to increase with decreasing ionic strength for the C-18 column. However, for the SOL column, this was not the case: the EOF showed a general reduction as the ionic strength was decreased. The greatest anomaly was observed on changing the acetonitrile composition: the EOF showed a consistent decline with increasing organic, whereas the EOF in both the open capillary and C-18 column decreased and then started to rise with acetonitrile contents above 70% (v/v).
引用
收藏
页码:1820 / 1825
页数:6
相关论文
共 30 条
[1]   Resin coating for capillaries giving a net positive charge and great potential for customised modification of surface properties [J].
Burt, H ;
Lewis, DM ;
Tapley, KN .
JOURNAL OF CHROMATOGRAPHY A, 1996, 739 (1-2) :367-371
[2]   CAPILLARY ELECTROPHORETIC SEPARATION OF PROTEINS USING STABLE, HYDROPHILIC POLY(ACRYLOYLAMINOETHOXYETHANOL)-COATED COLUMNS [J].
CHIARI, M ;
NESI, M ;
SANDOVAL, JE ;
PESEK, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :1-13
[3]   Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries [J].
Choudhary, G ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :161-183
[4]  
Euerby MR, 1997, J MICROCOLUMN SEP, V9, P373
[5]  
FORET F, 1993, CAPILLARY ZONE ELECT, pCH4
[6]   TABLE OF ISOTACHOPHORETIC INDEXES .1. SIMULATED QUALITATIVE AND QUANTITATIVE INDEXES OF 287 ANIONIC SUBSTANCES IN THE RANGE PH 3-10 [J].
HIROKAWA, T ;
NISHINO, M ;
AOKI, N ;
KISO, Y ;
SAWAMOTO, Y ;
YAGI, T ;
AKIYAMA, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 271 (02) :D1-D106
[7]   CHARGED SURFACE-COATINGS FOR CAPILLARY ELECTROPHORESIS [J].
HUANG, MX ;
YI, GL ;
BRADSHAW, JS ;
LEE, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (03) :199-205
[8]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION [J].
HUANG, XH ;
LUCKEY, JA ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :766-770
[9]  
Kitagawa S, 1997, J MICROCOLUMN SEP, V9, P347, DOI 10.1002/(SICI)1520-667X(1997)9:5<347::AID-MCS2>3.0.CO
[10]  
2-1