Quantec SC rotary instruments versus hand files for gutta-percha removal in root canal retreatment

被引:71
作者
Betti, LV [1 ]
Bramante, CM [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Endodont, BR-05508 Sao Paulo, Brazil
关键词
gutta-percha removal; nickel-titanium; Quantec System; root canal retreatment; rotary instruments;
D O I
10.1046/j.1365-2591.2001.00424.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The purpose of this study was to compare Quantec SC rotary instruments and hand files for removal of gutta-percha during retreatment. Methodology Twenty maxillary central incisors with a single straight canal were selected. The canals were instrumented and filled before the teeth were randomly divided into two groups of 10 specimens each. In group I Quantec SC rotary instruments were used for filling removal and in group 2, hand files and solvent. The following factors were evaluated: time taken to reach working length, time for gutta-percha removal, total time, apically extruded material during filling removal and number of fractured instruments, Radiographs were taken and the teeth were grooved longitudinally and split. The canal walls of each half and the radiographs were evaluated visually for cleanliness. They were then digitized using a scanner and the residual debris assessed. The analysis was carried out In the cervical, middle and apical thirds separately as well for the whole canal. Results The time for root filling removal was significantly less when Quantec SC was used (P < 0.05). The amount of apically extruded material was not significantly different between the groups (P > 0.05). Direct evaluation of the canal walls revealed that hand files and solvent demonstrated better cleanliness In the cervical third and in whole canal (P < 0.05). Radiographic analysis demonstrated that hand files performed significantly better when viewed in a mesiodistal direction (P < 0.05). Conclusions Although Quantec SC instruments took less time, hand instruments and solvent cleaned canals more effectively.
引用
收藏
页码:514 / 519
页数:6
相关论文
共 20 条
[1]  
AUN CE, 1989, REV FACULDADE ODONTO, V2, P63
[2]   Comparison of debris extruded apically in straight canals: Conventional filing versus Profile .04 Taper Series 29 [J].
Beeson, TJ ;
Hartwell, GR ;
Thornton, JD ;
Gunsolley, JC .
JOURNAL OF ENDODONTICS, 1998, 24 (01) :18-22
[3]   A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals [J].
Bishop, K ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :25-34
[4]   Efficacy of Quantec rotary instruments for gutta-percha removal [J].
Bramante, CM ;
Betti, LV .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (05) :463-467
[5]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[6]   ENDODONTIC RETREATMENT - CASE SELECTION AND TECHNIQUE .1. CRITERIA FOR CASE SELECTION [J].
FRIEDMAN, S ;
STABHOLZ, A .
JOURNAL OF ENDODONTICS, 1986, 12 (01) :28-35
[7]   EFFICACY OF REMOVING GLASS IONOMER CEMENT, ZINC-OXIDE EUGENOL, AND EPOXY-RESIN SEALERS FROM RETREATED ROOT CANALS [J].
FRIEDMAN, S ;
MOSHONOV, J ;
TROPE, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (05) :609-612
[8]   ENDODONTIC RETREATMENT - CASE SELECTION AND TECHNIQUE .3. RETREATMENT TECHNIQUES [J].
FRIEDMAN, S ;
STABHOLZ, A ;
TAMSE, A .
JOURNAL OF ENDODONTICS, 1990, 16 (11) :543-549
[9]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[10]  
Hulsmann M, 1997, INT ENDOD J, V30, P227