Skin entrance radiation dose in an interventional radiology procedure

被引:19
作者
Chu, Robert Y. L.
Thomas, George
Maqbool, Feroz
机构
[1] Vet Affairs Med Ctr, Radiol Serv 114, Oklahoma City, OK 73104 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Dept Radiol Sci, Oklahoma City, OK 73190 USA
[3] St Anthony Hosp, FRank C Love Canc Inst, Oklahoma City, OK 73101 USA
来源
HEALTH PHYSICS | 2006年 / 91卷 / 01期
关键词
skin dose; effective dose; fluoroscopy; x-ray imaging;
D O I
10.1097/01.HP.0000198784.94210.1f
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Monitoring of skin entrance radiation exposure in lengthy interventional procedures has been recommended because of the potential for skin injury. Fluoroscopy duration and dose-area product (DAP) are readily available real-time measurements. It would be of interest to study the correlation of these parameters and skin entrance radiation. Twenty neurological interventional procedures performed through the aortic arch were monitored. Two pieces of GafChromic XR Type R film were placed between the patient and the examination table. An observer recorded the fluoroscopy duration and DAP for each phase of the procedure. Each film was scanned post-procedure in RBG mode, and then the image was analyzed for peak skin entrance radiation dose (in air kerma). All DAP values were corrected according to a calibration with an ion chamber. With the DAP values for the respective phases of a procedure, the effective dose in a Reference Man was calculated. For these twenty cases, the means and standard deviations were 17.2 +/- 6.4 min for x ray on-time, 256 +/- 65 Gy cm(-2) for DAP, 94 +/- 34 cGy for peak skin entrance dose in air kerma, and 19.2 +/- 5.0 mSv for effective dose, respectively. The peak skin entrance dose was correlated to fluoroscopy duration, DAP, and effective dose with the r(2)-values of 0.48, 0.46, and 0.09, respectively. The correlation with DAP or fluoroscopy duration was not sufficiently strong to infer skin entrance dose from either of these parameters. Therefore, skin entrance dose should be determined directly.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 28 条
[1]
Amano Masafumi, 2002, Nihon Hoshasen Gijutsu Gakkai Zasshi, V58, P420
[2]
Amano Masafumi, 2003, Nihon Hoshasen Gijutsu Gakkai Zasshi, V59, P121
[3]
Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology [J].
Bor, D ;
Sancak, T ;
Olgar, T ;
Elcim, Y ;
Adanali, A ;
Sanlidilek, U ;
Akyar, S .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) :315-322
[4]
Dosimetric evaluation of GAFCHROMIC® XR type T and XR type R films [J].
Dini, Sharifeh A. ;
Koona, Rafiq A. ;
Ashburn, John R. ;
Meigooni, Ali S. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01) :114-134
[5]
Patient dosimetry during coronary interventions: A comprehensive analysis [J].
Efstathopoulos, EP ;
Karvouni, E ;
Kottou, S ;
Tzanalaridou, E ;
Korovesis, S ;
Giazitzoglou, E ;
Katritsis, DG .
AMERICAN HEART JOURNAL, 2004, 147 (03) :468-475
[6]
MEASUREMENT OF ABSORBED DOSES NEAR METAL AND DENTAL MATERIAL INTERFACES IRRADIATED BY X-RAY AND GAMMA-RAY THERAPY BEAMS [J].
FARAHANI, M ;
EICHMILLER, FC ;
MCLAUGHLIN, WL .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :369-385
[7]
FEYGELMAN VM, 1992, AJNR, V13, P820
[8]
Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures [J].
Fletcher, DW ;
Miller, DL ;
Balter, S ;
Taylor, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (04) :391-397
[9]
Measuring skin dose with radiochromic dosimetry film in the cardiac catheterization laboratory [J].
Giles, ER ;
Murphy, PH .
HEALTH PHYSICS, 2002, 82 (06) :875-880
[10]
Evaluation of an on-line patient exposure meter in neuroradiology [J].
Gkanatsios, NA ;
Huda, W ;
Peters, KR ;
Freeman, JA .
RADIOLOGY, 1997, 203 (03) :837-842