Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology

被引:87
作者
Bor, D [1 ]
Sancak, T
Olgar, T
Elcim, Y
Adanali, A
Sanlidilek, U
Akyar, S
机构
[1] Ankara Univ, Fac Engn, Dept Engn Phys, TR-06100 Ankara, Turkey
[2] Ankara Univ, Ibni Sina Hosp, Fac Med, Dept Intervent Radiol, TR-06100 Ankara, Turkey
关键词
D O I
10.1259/bjr/29942833
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, measurements of dose-area product (DAP) and entrance dose were carried out simultaneously in a sample of 162 adult patients Who underwent different interventional examinations. Effective doses for each measurement technique were estimated using the conversion factors that have been determined for specific X-ray views in a mathematical phantom. Exposure conditions used in clinical practice never match these theoretical models exactly, and deviations from the assumed standard conditions cause uncertainties in effective dose estimations. Higher effective dose values are found if the air kerma results are used rather than DAP readings, both for patient and Rando phantom Studies. Comparison of DAP, fluoroscopy times and skin doses were made with published data. DAP measurement for the effective dose calculation and thermoluminescent dosimeter for the skin dose estimates Lire found to be the most reliable methods for patient dosimetry..
引用
收藏
页码:315 / 322
页数:8
相关论文
共 31 条
[1]  
BERGERON P, 1994, AM J NEURORADIOL, V15, P1809
[2]  
BROADHEAD DA, 1996, P INT C RAD PROT VIE, V3, P438
[3]   ASSESSMENT OF ORGAN RADIATION-DOSES AND ASSOCIATED RISK FOR DIGITAL BIFEMORAL ARTERIOGRAPHY [J].
CASTELLANO, IA ;
MCNEILL, JG ;
THORP, NC ;
DANCE, DR ;
RAPHAEL, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) :502-507
[4]   Estimation of effective dose in some digital angiographic and interventional procedures [J].
Cruces, RR ;
García-Granados, J ;
Romero, FJD ;
Armas, JH .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :42-47
[5]   RADIATION-DOSES AND SOMATIC RISK TO PATIENTS DURING CARDIAC RADIOLOGICAL PROCEDURES [J].
FAULKNER, K ;
LOVE, HG ;
SWEENEY, JK ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (700) :359-363
[6]   Dosimetric methods for and influence of exposure parameters on the establishment of reference doses for examinations using fluoroscopy [J].
Gfirtner, H ;
Giesse, E ;
Schmidt, T .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :121-128
[7]   A new Diamentor for measuring kerma-area product and air-kerma simultaneously [J].
Gfirtner, H ;
Stieve, FE ;
Wild, J .
MEDICAL PHYSICS, 1997, 24 (12) :1954-1959
[8]  
HART D, 1994, 262NRPBSR
[9]   Patient dose measurements from femoral angiography [J].
Hoskins, PR ;
Gillespie, I ;
Ireland, HM .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (828) :1159-1164
[10]  
International Commission on Radiological Protection, 1991, ICRP PUBL