Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation

被引:79
作者
Hayashida, Kentaro [1 ]
Bouvier, Erik [1 ]
Lefevre, Thierry [1 ]
Hovasse, Thomas [1 ]
Morice, Marie-Claude [1 ]
Chevalier, Bernard [1 ]
Romano, Mauro [1 ]
Garot, Philippe [1 ]
Mylotte, Darren [1 ]
Farge, Arnaud [1 ]
Donzeau-Gouge, Patrick [1 ]
Cormier, Bertrand [1 ]
机构
[1] Inst Cardiovasc Paris Sud, Massy, France
关键词
annulus; aortic regurgitation; ortic stenosis; CT; transcatheter aortic valve implantation; MULTISLICE COMPUTED-TOMOGRAPHY; CARDIOVASCULAR MAGNETIC-RESONANCE; HIGH-RISK PATIENTS; PARAVALVULAR REGURGITATION; ANNULUS DIMENSIONS; ECHOCARDIOGRAPHY; REPLACEMENT; ROOT; RECOMMENDATIONS; INTERVENTIONS;
D O I
10.4244/EIJV8I5A85
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Transoesophageal echocardiography (TEE) is considered the gold standard method for annulus measurement in transcatheter aortic valve implantation (TAVI). However, computed tomography (CT) has potential advantages compared to TEE. We sought to assess the impact of CT-guided valve sizing on post-procedural aortic regurgitation (AR). Methods and results: We compared procedural characteristics and clinical outcomes in patients undergoing either TEE-guided or CT-guided TAVI. Among 350 consecutive TAVI recipients, the mean age was 83.2 +/- 6.4 years and the logistic EuroSCORE was 22.4 +/- 11.2%. The mean Diam-TEE was similar in both groups (22.3 +/- 1.9 mm vs. .0 +/- 1.8 mm, p=0.092). The mean annulus diameter by CT (mDiam-CT) was larger than mean Diam-TEE (23.6 +/- 2.0 mm vs. 22.3 +/- 1.9 mm, p<0.001), and resulted in larger valve implant sizes compared to the TEE-guided group (25.8 +/- 2.1 mm vs. 25.0 +/- 1.9 mm, p<0.001). The incidence of post-procedural AR >= grade 2 was significantly reduced in the CT-guided group (15.4% vs. 24.0%, p=0.044), with a similar risk of annulus rupture (0.6% vs. 1.7%, p=0.31). The only predictor of post-procedural AR >= 2 was the "valve/mDiam-CT ratio" (HR 0.36 by increase of 0.1, 95% Cl: 0.17-0.77, p=0.008) by multivariate analysis. Conclusion: CT-guided valve sizing in TAVI significantly reduces the incidence of post-procedural AR compared to TEE sizing. This strategy may have the potential to improve clinical outcomes.
引用
收藏
页码:546 / 555
页数:10
相关论文
共 29 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   Usefulness of TEE as the Primary Imaging Technique to Guide Transcatheter Transapical Aortic Valve Implantation [J].
Bagur, Rodrigo ;
Rodes-Cabau, Josep ;
Doyle, Daniel ;
De Larochelliere, Robert ;
Villeneuve, Jacques ;
Lemieux, Jerome ;
Bergeron, Sebastien ;
Cote, Melanie ;
Bertrand, Olivier F. ;
Pibarot, Philippe ;
Dumont, Eric .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) :115-124
[3]   Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method [J].
Blanke, Philipp ;
Siepe, Matthias ;
Reinoehl, Jochen ;
Zehender, Manfred ;
Beyersdorf, Friedhelm ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :750-758
[4]   Aortic Root Measurement by Cardiovascular Magnetic Resonance Specification of Planes and Lines of Measurement and Corresponding Normal Values [J].
Burman, Elisabeth D. ;
Keegan, Jennifer ;
Kilner, Philip J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (02) :104-113
[5]  
Carrie D, 2010, EUR HEART J, V31, P167
[6]   Evaluation of Multislice Computed Tomography Early After Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Bioprosthesis [J].
Caudron, Jerome ;
Fares, Jeannette ;
Hauville, Camille ;
Cribier, Alain ;
Dacher, Jean-Nicolas ;
Tron, Christophe ;
Bauer, Fabrice ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Eltchaninoff, Helene .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (06) :873-881
[7]   Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative Measurement [J].
Dashkevich, Alexey ;
Blanke, Philipp ;
Siepe, Matthias ;
Pache, Gregor ;
Langer, Mathias ;
Schlensak, Christian ;
Beyersdorf, Friedhelm .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :709-715
[8]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[9]   Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence [J].
Detaint, Delphine ;
Lepage, Laurent ;
Himbert, Dominique ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Iung, Bernard ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :821-827
[10]   Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT [J].
Doddamani, Sanjay ;
Grushko, Michael J. ;
Makaryus, Amgad N. ;
Jain, Vineet R. ;
Bello, Ricardo ;
Friedman, Mark A. ;
Ostfeld, Robert J. ;
Malhotra, Divya ;
Boxt, Lawrence M. ;
Haramati, Linda ;
Spevack, Daniel M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02) :175-181