Continuous measurement of hemodynamic alterations during pharmacologic cardiovascular stress using automated impedance cardiography

被引:15
作者
Scherhag, AW
Pfleger, S
deMey, C
Schreckenberger, AB
Staedt, U
Heene, DL
机构
[1] UNIV HEIDELBERG,MED CLIN,FAC CLIN MED,D-6800 MANNHEIM,GERMANY
[2] INST CLIN PHARMACOL,HOEHENKIRCHEN SIEGERTSBR,GERMANY
关键词
CORONARY-ARTERY DISEASE; THORACIC ELECTRICAL BIOIMPEDANCE; DIPYRIDAMOLE-ECHOCARDIOGRAPHY TEST; CARDIAC-OUTPUT ESTIMATION; M-MODE ECHOCARDIOGRAPHY; STROKE VOLUME; DOPPLER ECHOCARDIOGRAPHY; MYOCARDIAL-ISCHEMIA; HEALTHY-VOLUNTEERS; DOBUTAMINE;
D O I
10.1177/009127009703700118
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The contribution of computerized impedance cardiography in monitoring and differentiating cardiovascular responses to pharmacologic stress after the administration of dipyridamole (group 1, n = 24) or dobutamine (group 2, n = 26) was investigated during stress echocardiography. Heart rate, stroke volume index, cardiac index and systemic vascular resistance index were evaluated continuously with an automated, computerized, signal-averaged impedance cardiography system. Dipyridamole had little average effect on heart rate, stroke volume index, and cardiac index. The responses were similar in patients with positive (n = 9) or negative (n = 15) stress echocardiography test results (as characterized by echocardiographic wall-motion abnormalities). Dobutamine induced a similar mean increase in heart rate in patients with negative (n = 13) or positive (n = 13) results on stress echocardiography. The mean increase in stroke volume index induced by dobutamine was greater in patients with negative stress echocardiography test results than in patients with stress-induced wall-motion abnormalities. This distinction was also seen in the cardiac index; the mean change in patients with negative stress echocardiography test results was larger than in patients with positive results. It is concluded that automated computerized impedance cardiography not only allows surveying and monitoring hemodynamic changes during pharmacologic stress echocardiography but also contributes to differentiation of pathologic stress responses.
引用
收藏
页码:S21 / S28
页数:8
相关论文
共 33 条
[1]   A COMPARISON OF ATTENUATION COMPENSATED VOLUME FLOW BASED DOPPLER ECHOCARDIOGRAPHY AND IMPEDANCE CARDIOGRAPHY IN HEALTHY-VOLUNTEERS [J].
ACTON, G ;
BROOM, C .
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1990, 4 (05) :290-297
[2]   DOBUTAMINE STRESS ECHOCARDIOGRAPHY - SENSITIVITY, SPECIFICITY, AND PREDICTIVE VALUE FOR FUTURE CARDIAC EVENTS [J].
AFRIDI, I ;
QUINONES, MA ;
ZOGHBI, WA ;
CHEIRIF, J .
AMERICAN HEART JOURNAL, 1994, 127 (06) :1510-1515
[3]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[4]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[5]   COMPARISON OF 4 NONINVASIVE TECHNIQUES TO MEASURE STROKE VOLUME - DUAL-BEAM DOPPLER ECHOAORTOGRAPHY, ELECTRICAL-IMPEDANCE CARDIOGRAPHY, MECHANOSPHYGMOGRAPHY AND M-MODE ECHOCARDIOGRAPHY OF THE LEFT-VENTRICLE [J].
BREITHAUPT, K ;
ERB, KA ;
NEUMANN, B ;
WOLF, GK ;
BELZ, GG .
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1990, 4 (04) :203-209
[6]   DETERMINATION OF CARDIAC-OUTPUT DURING POSITIVE ENDEXPIRATORY PRESSURE - NONINVASIVE ELECTRICAL BIOIMPEDANCE COMPARED WITH STANDARD THERMODILUTION [J].
CASTOR, G ;
MOLTER, G ;
HELMS, J ;
NIEDERMARK, I ;
ALTMAYER, P .
CRITICAL CARE MEDICINE, 1990, 18 (05) :544-546
[7]   SIMULTANEOUS MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION, THORACIC ELECTRICAL BIOIMPEDANCE AND DOPPLER ULTRASOUND [J].
CASTOR, G ;
KLOCKE, RK ;
STOLL, M ;
HELMS, J ;
NIEDERMARK, I .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) :133-138
[8]  
DEMEY C, 1988, AVIAT SPACE ENVIR MD, V59, P57
[9]  
DEMEY C, 1993, BRIT J CLIN PHARMACO, V35, P349
[10]  
DEMEY C, 1992, BRIT J CLIN PHARMACO, V34, P88