Capillary inserts in microcirculatory systems

被引:5
作者
Atencia, J
Beebe, DJ
机构
[1] 2142 Engineering Centers, Building 1550, Madison, WI 53706, Engineering Drive
关键词
D O I
10.1039/b514068d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic loops (i.e. closed fluid paths) pose specific practical challenges such as priming, introducing analytes or reagents in a controlled way and sampling products. In this technical note we address these three issues using a removable part of the microchannel that we call a 'capillary insert'.
引用
收藏
页码:575 / 577
页数:3
相关论文
共 16 条
[1]   Steady flow generation in microcirculatory systems [J].
Atencia, J ;
Beebe, DJ .
LAB ON A CHIP, 2006, 6 (04) :567-574
[2]   Long-term monitoring of bacteria undergoing programmed population control in a microchemostat [J].
Balagaddé, FK ;
You, LC ;
Hansen, CL ;
Arnold, FH ;
Quake, SR .
SCIENCE, 2005, 309 (5731) :137-140
[3]   Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate [J].
Chen, JF ;
Wabuyele, M ;
Chen, HW ;
Patterson, D ;
Hupert, M ;
Shadpour, H ;
Nikitopoulos, D ;
Soper, SA .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :658-666
[4]   Thermosiphon-based PCR reactor: Experiment and modeling [J].
Chen, ZY ;
Qian, SZ ;
Abrams, WR ;
Malamud, D ;
Bau, HH .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3707-3715
[5]   Transport of bubbles in square microchannels [J].
Cubaud, T ;
Ho, CM .
PHYSICS OF FLUIDS, 2004, 16 (12) :4575-4585
[6]   Computerized microfluidic cell culture using elastomeric channels and Braille displays [J].
Gu, W ;
Zhu, XY ;
Futai, N ;
Cho, BS ;
Takayama, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (45) :15861-15866
[7]   A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion [J].
Hansen, CL ;
Skordalakes, E ;
Berger, JM ;
Quake, SR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (26) :16531-16536
[8]   CALCULATION OF LIQUID DROPLET PROFILES FROM CLOSED-FORM SOLUTION OF YOUNG-LAPLACE EQUATION [J].
KU, TC ;
RAMSEY, JH ;
CLINTON, WC .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1968, 12 (06) :441-&
[9]   Mice that lack the angiogenesis inhibitor, thrombospondin 2, mount an altered foreign body reaction characterized by increased vascularity [J].
Kyriakides, TR ;
Leach, KJ ;
Hoffman, AS ;
Ratner, BD ;
Bornstein, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (08) :4449-4454
[10]   Recirculation of nanoliter volumes within microfluidic channels [J].
Lammertink, RGH ;
Schlautmann, S ;
Besselink, GAJ ;
Schasfoort, RBM .
ANALYTICAL CHEMISTRY, 2004, 76 (11) :3018-3022