Thermosiphon-based PCR reactor: Experiment and modeling

被引:81
作者
Chen, ZY
Qian, SZ
Abrams, WR
Malamud, D
Bau, HH [1 ]
机构
[1] Univ Penn, Sch Engn & Appl Sci, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Dent Med, Dept Biochem, Philadelphia, PA 19104 USA
关键词
D O I
10.1021/ac049914k
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A self-actuated, flow-cycling polymerase chain reaction (PCR) reactor that takes advantage of buoyancy forces to continuously circulate reagents in a closed loop through various thermal zones has been constructed, tested, and modeled. The heating required for the PCR is advantageously used to induce fluid motion without the need for a pump. Flow velocities on the order of millimeters per second are readily attainable. In our preliminary prototype, we measured a cross-sectionally averaged velocity of 2.5 mm/s and a cycle time of 104 s. The flow velocity is nearly independent of the loop's length, making the device readily scalable. Successful amplifications of 700- and 305-bp fragments of Bacillus cereus genomic DNA have been demonstrated. Since the device does not require any moving parts, it is particularly suitable for miniature systems.
引用
收藏
页码:3707 / 3715
页数:9
相关论文
共 33 条
[1]
A magneto-hydrodynamically controlled fluidic network [J].
Bau, HH ;
Zhu, JZ ;
Qian, SZ ;
Xiang, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) :205-216
[2]
ON THE STABILITY AND FLOW REVERSAL OF AN ASYMMETRICALLY HEATED OPEN CONVECTION LOOP [J].
BAU, HH ;
TORRANCE, KE .
JOURNAL OF FLUID MECHANICS, 1981, 109 (AUG) :417-433
[3]
BAU HH, 2001, 23884 MEMS
[4]
Infectious disease - PCR detection of bacteria in seven minutes [J].
Belgrader, P ;
Benett, W ;
Hadley, D ;
Richards, J ;
Stratton, P ;
Mariella, R ;
Milanovich, F .
SCIENCE, 1999, 284 (5413) :449-450
[5]
A reusable flow-through polymerase chain reaction instrument for the continuous monitoring of infectious biological agents [J].
Belgrader, P ;
Elkin, CJ ;
Brown, SB ;
Nasarabadi, SN ;
Langlois, RG ;
Milanovich, FP ;
Colston, BW ;
Marshall, GD .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3446-3450
[6]
BIRD RB, 1960, TRANSPORT PHENOMENA, P399
[7]
Exponential DNA replication by laminar convection [J].
Braun, D ;
Goddard, NL ;
Libchaber, A .
PHYSICAL REVIEW LETTERS, 2003, 91 (15)
[8]
Renewable microcolumns for automated DNA purification and flow-through amplification: from sediment samples through polymerase chain reaction [J].
Bruckner-Lea, CJ ;
Tsukuda, T ;
Dockendorff, B ;
Follansbee, JC ;
Kingsley, MT ;
Ocampo, C ;
Stults, JR ;
Chandler, DP .
ANALYTICA CHIMICA ACTA, 2002, 469 (01) :129-140
[9]
Design and theoretical evaluation of a novel microfluidic device to be used for PCR [J].
Bu, MQ ;
Melvin, T ;
Ensell, G ;
Wilkinson, JS ;
Evans, AGR .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) :S125-S130
[10]
A miniaturized cyclic PCR device - modeling and experiments [J].
Chou, CF ;
Changrani, R ;
Roberts, P ;
Sadler, D ;
Burdon, J ;
Zenhausern, F ;
Lin, S ;
Mulholland, A ;
Swami, N ;
Terbrueggen, R .
MICROELECTRONIC ENGINEERING, 2002, 61-2 :921-925