Original report - Blood pool MR angiography of aortic stent-graft endoleak

被引:90
作者
Ersoy, H
Jacobs, P
Kent, CK
Prince, MR
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[2] Adv Magnet Inc, Cambridge, MA 02138 USA
[3] Cornell Univ, Weill Med Coll, Dept Vasc Surg, New York, NY 10021 USA
关键词
D O I
10.2214/ajr.182.5.1821181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our research was to investigate the value of a blood pool contrast agent in detecting endoleaks on MR angiography after endoluminal stent-graft repair of infrarenal aortic aneurysms. CONCLUSION. Blood pool MR angiography using Ferumoxytol reveals more aortic stent-graft endoleaks than does CT angiography and depicts more endoleaks 24 hr after administration than during the immediate arterial phase because of a 50-fold increase in the volume of enhancement in the aneurysmal sac outside the stent-graft.
引用
收藏
页码:1181 / 1186
页数:6
相关论文
共 11 条
[1]   Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating:: Pilot study [J].
Ahlström, KH ;
Johansson, LO ;
Rodenburg, JB ;
Ragnarsson, AS ;
Åkeson, P ;
Börseth, A .
RADIOLOGY, 1999, 211 (03) :865-869
[2]   MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent [J].
Anzai, Y ;
Prince, MR ;
Chenevert, TL ;
Maki, JH ;
Londy, F ;
London, M ;
McLachlan, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :209-214
[3]   Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition [J].
Golzarian, J ;
Dussaussois, L ;
Abada, HT ;
Gevenois, PA ;
Van Gansbeke, D ;
Ferreira, J ;
Struyven, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :329-331
[4]   Intestinal and peritoneal bleeding: Detection with an intravascular contrast agent and fast three-dimensional MR imaging - Preliminary experience from an experimental study [J].
Hilfiker, PR ;
Zimmermann-Paul, GG ;
Schmidt, M ;
Klotz, HP ;
Kacl, GM ;
Debatin, JF .
RADIOLOGY, 1998, 209 (03) :769-774
[5]   Comparison of three dimensional magnetic resonance imaging in conjunction with a blood pool contrast agent and nuclear scintigraphy for the detection of experimentally induced gastrointestinal bleeding [J].
Hilfiker, PR ;
Weishaupt, D ;
Kacl, GM ;
Hetzer, FH ;
Griff, MD ;
Ruehm, SG ;
Debatin, JF .
GUT, 1999, 45 (04) :581-587
[6]   NIR contrast material for vascular enhancement: Value of superparamagnetic iron oxide [J].
MayoSmith, WW ;
Saini, S ;
Slater, G ;
Kaufman, JA ;
Sharma, P ;
Hahn, PF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (01) :73-77
[7]   ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC-ANEURYSM - VALUE OF POSTOPERATIVE FOLLOW-UP WITH HELICAL CT [J].
ROZENBLIT, A ;
MARIN, ML ;
VEITH, FJ ;
CYNAMON, J ;
WAHL, SI ;
BAKAL, CW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1473-1479
[8]   Clear fluid from a thyroid cyst [J].
Weiss, RE .
THYROID, 2000, 10 (02) :195-196
[9]  
White GH, 1997, J ENDOVASC SURG, V4, P152, DOI 10.1583/1074-6218(1997)004<0152:EAACOE>2.0.CO
[10]  
2