Expandable cylindrical cages in the cervical spine: a review of 22 cases

被引:32
作者
Auguste, KI [1 ]
Chin, C [1 ]
Acosta, FL [1 ]
Ames, CP [1 ]
机构
[1] Univ Calif San Francisco, Sch Med, Dept Neurol Surg, San Francisco, CA 94143 USA
关键词
cervical spine; spinal fusion; corpectomy; expandable cage; spinal instrumentation;
D O I
10.3171/spi.2006.4.4.285
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Expandable cylindrical cages (ECCs) have been utilized Successfully to reconstruct the thoracic and lumbar spine. Their advantages include ease of insertion, reduced endplate trauma, direct application/maintenance of interbody distraction force, and one-step kyphosis correction. The authors present their experience with ECCs in the reconstruction of the cervical spine in patients with various pathological conditions. Methods. Data obtained in 22 patients were reviewed retrospectively. A standard anterior cervical corpectomy was performed in all cases. Local vertebral body bone was harvested for use as graft material. Patients underwent pre- and postoperative assessment involving the visual analog scale (VAS), Nurick grading system for determining myelopathy disability, and radiographic studies to determine cervical kyphosis/lordosis and cage subsidence. Fusion 41 was defined as the absence of motion on flex ion-extension x-ray films. Sixteen patients presented with spondylotic myelopathy, two with osteomyelitis, two with fracture, one with tumor metastasis, and one with severe stenosis. Fourteen patients underwent supplemental posterior spinal fusion, seven underwent single-level corpectomy, and 15 patients underwent multilevel corpectomy. No perioperative complications Occurred. The mean follow-up period was 22 months. In 11 patients with preexisting kyphosis (mean deformity +19 degrees), the mean correction was 22 degrees. There was no statistically significant difference in subsidence between single- and multilevel corpectomy or between 360 degrees fusion and anterior fusion alone. The VAS scores improved by 35%, and the Nurick grade improved by 31%. The fusion rate was 100%. Conclusions. The preliminary results support the use of ECCs in the cervical spine in the treatment of patients with various disease processes. No significant subsidence was noted, and pain and functional scores improved in all cases. Expandable cylindrical cages appear to be well suited for cervical reconstruction and for correcting sagittal malalignment.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 56 条
[1]
STABILIZATION OF THE CERVICAL SPINE BY ANTERIOR FUSION [J].
BAILEY, RW ;
BADGLEY, CE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (04) :565-594
[2]
Incidence of dysphagia after anterior cervical spine surgery - A prospective study [J].
Bazaz, R ;
Lee, MJ ;
Yoo, JU .
SPINE, 2002, 27 (22) :2453-2458
[3]
CERVICAL SPONDYLOTIC MYELOPATHY [J].
BERNHARDT, M ;
HYNES, RA ;
BLUME, HW ;
WHITE, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :119-128
[4]
Anterior cervical interbody fusion using autogeneic and allogeneic bone graft substrate: A prospective comparative analysis [J].
Bishop, RC ;
Moore, KA ;
Hadley, MN .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :206-210
[5]
INTERBODY LUMBAR FUSION USING A CARBON-FIBER CAGE IMPLANT VERSUS ALLOGRAFT BONE - AN INVESTIGATIONAL STUDY IN THE SPANISH GOAT [J].
BRANTIGAN, JW ;
MCAFEE, PC ;
CUNNINGHAM, BW ;
WANG, H ;
ORBEGOSO, CM .
SPINE, 1994, 19 (13) :1436-1444
[6]
BRODKE DS, 1992, SPINE, V17, P427
[7]
The use of bone allografts in the spine [J].
Buttermann, GR ;
Glazer, PA ;
Bradford, DS .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (324) :75-85
[8]
Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model [J].
Clausen, JD ;
Ryken, TC ;
Traynelis, VC ;
Sawin, PD ;
Dexter, F ;
Goel, VK .
JOURNAL OF NEUROSURGERY, 1996, 84 (06) :1039-1045
[9]
THE ANTERIOR APPROACH FOR REMOVAL OF RUPTURED CERVICAL DISKS [J].
CLOWARD, RB .
JOURNAL OF NEUROSURGERY, 1958, 15 (06) :602-617
[10]
Connolly PJ, 1996, J SPINAL DISORD, V9, P202