Implementation and evaluation of a new pulse sequence for rapid acquisition of double inversion recovery images for simultaneous suppression of white matter and CSF

被引:51
作者
Bedell, BJ [1 ]
Narayana, PA [1 ]
机构
[1] Univ Texas, Sch Med, Dept Radiol, Houston, TX 77030 USA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 03期
关键词
brain; double inversion recovery; magnetic resonance imaging; multiple sclerosis;
D O I
10.1002/jmri.1880080305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
We describe a fast double inversion recovery (DIR) imaging sequence that effectively attenuates signal from both white matter and cerebrospinal fluid (CSF). The pulse sequence uses a novel inversion/excitation scheme and fast spin-echo readout to maximize scan efficiency. The white matter/CSF suppressed images can be acquired from the entire brain in similar to 6 minutes. Evaluation of the fast DIR sequence on patients with multiple sclerosis (MS) demonstrates high lesion conspicuity.
引用
收藏
页码:544 / 547
页数:4
相关论文
共 11 条
[1]
A dual approach for minimizing false lesion classifications on magnetic resonance images [J].
Bedell, BJ ;
Narayana, PA ;
Wolinsky, JS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :94-102
[2]
3D RECONSTRUCTION OF THE BRAIN FROM MAGNETIC-RESONANCE IMAGES USING A CONNECTIVITY ALGORITHM [J].
CLINE, HE ;
DUMOULIN, CL ;
HART, HR ;
LORENSEN, WE ;
LUDKE, S .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :345-352
[3]
A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185
[4]
USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[5]
MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[6]
CORRELATION OF SPECTROSCOPY AND MAGNETIZATION-TRANSFER IMAGING IN THE EVALUATION OF DEMYELINATING LESIONS AND NORMAL APPEARING WHITE-MATTER IN MULTIPLE-SCLEROSIS [J].
HIEHLE, JF ;
LENKINSKI, RE ;
GROSSMAN, RI ;
DOUSSET, V ;
RAMER, KN ;
SCHNALL, MD ;
COHEN, JA ;
GONZALEZSCARANO, F .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :285-293
[7]
REPRODUCTIBILITY OF NONPARAMETRIC FEATURE MAP SEGMENTATION FOR DETERMINATION OF NORMAL HUMAN INTRACRANIAL VOLUMES WITH MR-IMAGING DATA [J].
JACKSON, EF ;
NARAYANA, PA ;
FALCONER, JC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :692-700
[8]
EFFECT OF RADIO-FREQUENCY INHOMOGENEITY CORRECTION ON THE REPRODUCIBILITY OF INTRACRANIAL VOLUMES USING MR IMAGE DATA [J].
NARAYANA, PA ;
BORTHAKUR, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) :396-400
[9]
SCALE-SPACE AND EDGE-DETECTION USING ANISOTROPIC DIFFUSION [J].
PERONA, P ;
MALIK, J .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (07) :629-639
[10]
NEW DIAGNOSTIC-CRITERIA FOR MULTIPLE-SCLEROSIS - GUIDELINES FOR RESEARCH PROTOCOLS [J].
POSER, CM ;
PATY, DW ;
SCHEINBERG, L ;
MCDONALD, WI ;
DAVIS, FA ;
EBERS, GC ;
JOHNSON, KP ;
SIBLEY, WA ;
SILBERBERG, DH ;
TOURTELLOTTE, WW .
ANNALS OF NEUROLOGY, 1983, 13 (03) :227-231