Application of polymeric surfactants in micellar electrokinetic chromatography-electrospray ionization mass spectrometry of benzodiazepines and benzoxazocine chiral drugs

被引:29
作者
Hou, JG [1 ]
Rizvi, SAA [1 ]
Zheng, J [1 ]
Shamsi, SA [1 ]
机构
[1] Georgia State Univ, Dept Chem, Ctr Biotechnol & Drug Design, Atlanta, GA 30303 USA
关键词
benzodiazepines; benzoxazocine; chiral separation; micellar electrokinetic chromatography-mass spectrometry; polymeric surfactants;
D O I
10.1002/elps.200500610
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Chiral micellar EKC (CMEKC) coupled to ESI-MS using polymeric surfactants as pseudostationary phases is investigated for simultaneous enantioseparation of two benzodiazepines, (+/-)-oxazepam ((+/-)-OXA) and (+/-)-lorazepam ((+/-)-LOR), and one benzoxazocine, (+/-)-nefopam ((+/-)-NEF). First, enantioselectivity and electrospray sensitivity of six chiral polymeric surfactants for all three chiral compounds are compared. Second, using poly(sodium N-undecenoyl-L-leucinate) as pseudostationary phase, the organic modifiers (methanol (MeOH), isopropanol, and ACN) are added into the running buffer to further improve chiral resolution (R-S). Next, a CMEKC-ESI-MS method for the simultaneous enantioseparation of two benzodiazepines is further developed by using a dipeptide polymeric surfactant, poly(sodium N-undecenoxy carbonyl-L,L-leucyl-valinate) (poly-L,L-SUCLV). The CMEKC conditions including nebulizer pressure, capillary length, ammonium acetate concentration, pH, poly-L,L-SUCLV concentration, and capillary temperature were optimized to achieve maximum chiral R-S and highest sensitivity of MS detection. The spray chamber parameters (drying gas temperature and drying gas flow rate) as well as sheath liquid conditions (MeOH content, pH, flow rate, and ionic strength) were found to significantly influence MS S/N of both (+/-)-OXA and (+/-)-LOR. Finally, a comparative study between simultaneous UV and MS detection showed high plate numbers, better chiral R-S, and enhanced detectability with CMEKC-MS. However, speed of analysis was faster using CMEKC-UV.
引用
收藏
页码:1263 / 1275
页数:13
相关论文
共 41 条
[1]
Simultaneous enantioseparation and tandem UV-MS detection of eight β-blockers in micellar electrokinetic chromatography using a chiral molecular micelle [J].
Akbay, C ;
Rizvi, SAA ;
Shamsi, SA .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1672-1683
[2]
Chiral separations using dipeptide polymerized surfactants: Effect of amino acid order [J].
Billiot, E ;
Macossay, J ;
Thibodeaux, S ;
Shamsi, SA ;
Warner, IM .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1375-1381
[3]
BLASCHKE G, 1986, ARZNEIMITTEL-FORSCH, V36-1, P893
[4]
SUPPRESSION OF CHIRAL RECOGNITION OF 3-HYDROXY-1,4-BENZODIAZEPINES DURING MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY WITH BILE-SALTS [J].
BOONKERD, S ;
DETAEVERNIER, MR ;
MICHOTTE, Y ;
VINDEVOGEL, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :238-241
[5]
DEVELOPMENT OF AN INSTRUMENTAL CONFIGURATION FOR PSEUDO-ELECTROCHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
DEKKERS, SEG ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :201-209
[6]
HIROTO O, 1995, J CHROMATOGR A, V716, P69
[7]
HIROTO O, 1998, J CHROMATOGR A, V794, P317
[8]
Surfactants usable for electrospray ionization mass spectrometry [J].
Ishihama, Y ;
Katayama, H ;
Asakawa, N .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :45-54
[9]
DETERMINATION OF ENANTIOMERIZATION BARRIERS BY COMPUTER-SIMULATION OF INTERCONVERSION PROFILES - ENANTIOMERIZATION OF DIAZIRIDINES DURING CHIRAL INCLUSION GAS-CHROMATOGRAPHY [J].
JUNG, M ;
SCHURIG, V .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (02) :529-534
[10]
Separation and detection of closely related peptides by micellar electrokinetic chromatography coupled with electrospray ionization mass spectrometry using the partial filling technique [J].
Koezuka, K ;
Ozaki, H ;
Matsubara, N ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :3-11