Ultrasound evaluation of liver fibrosis: preliminary experience with acoustic structure quantification (ASQ) software

被引:79
作者
Ricci, Paolo [1 ]
Marigliano, Chiara [1 ]
Cantisani, Vito [1 ]
Porfiri, Andrea [1 ]
Marcantonio, Andrea [1 ]
Lodise, Pietro [1 ]
D'Ambrosio, Ugo [1 ]
Labbadia, Giancarlo [2 ]
Maggini, Elena [1 ]
Mancuso, Ester [1 ]
Panzironi, Giovanna [1 ]
Di Segni, Mattia [1 ]
Furlan, Caterina [3 ]
Masciangelo, Raffaele [4 ]
Taliani, Gloria [3 ]
机构
[1] Univ Roma La Sapienza, Azienda Policlin Umberto 1, Dipartimento Sci Radiol Oncol & Anatomopatol, I-00161 Rome, Italy
[2] Univ Roma La Sapienza, Azienda Policlin Umberto 1, Dipartimento Med Interna & Special Med, I-00161 Rome, Italy
[3] Univ Roma La Sapienza, Azienda Policlin Umberto 1, Dipartimento Malattie Infett & Trop, I-00161 Rome, Italy
[4] Univ Roma La Sapienza, Azienda Policlin Umberto 1, Dipartimento Sanita Pubbl & Malattie Infett, I-00161 Rome, Italy
来源
RADIOLOGIA MEDICA | 2013年 / 118卷 / 06期
关键词
Acoustic structure quantification; Liver fibrosis; Fibroscan; TIME TISSUE ELASTOGRAPHY; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; DISEASE; BIOPSY;
D O I
10.1007/s11547-013-0940-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
The aim of our study was to assess the diagnostic accuracy of acoustic structure quantification (ASQ) ultrasound software in estimating the degree of hepatic fibrosis compared to Fibroscan and liver biopsy. Seventy-seven patients with chronic viral hepatitis B and C underwent standard ultrasound examination, ASQ, Fibroscan and liver biopsy. ASQ analysis was conducted by placing a single region of interest (ROI) on each image captured, and calculating mode, average and standard deviation. The sonographic technique was developed through a preliminary evaluation of 20 healthy volunteers. The area under the receiver operating characteristic (AUROC) curve for the diagnosis of cirrhosis (Fa parts per thousand yen4) with ASQ was 0.77, whereas for the diagnosis of any degree of fibrosis (Fa parts per thousand yen1) it was 0.71. The AUROC for the diagnosis of cirrhosis (Fa parts per thousand yen4) with Fibroscan was 0.98, while for the diagnosis of any degree of fibrosis (Fa parts per thousand yen1) it was 0.94. The difference between the AUROC was statistically significant (p < 0.05). ASQ is a promising new ultrasound software programme which offers encouraging results in the diagnosis of both liver cirrhosis (F=4) and fibrosis (Fa parts per thousand yen1). However, to date it has not attained the same level of diagnostic performance as Fibroscan.
引用
收藏
页码:995 / 1010
页数:16
相关论文
共 17 条
[1]
Viscoelasticity-based Staging of Hepatic Fibrosis with Multifrequency MR Elastography [J].
Asbach, Patrick ;
Klatt, Dieter ;
Schlosser, Beate ;
Biermer, Michael ;
Muche, Marion ;
Rieger, Anja ;
Loddenkemper, Christoph ;
Somasundaram, Rajan ;
Berg, Thomas ;
Hamm, Bernd ;
Braun, Juergen ;
Sack, Ingolf .
RADIOLOGY, 2010, 257 (01) :80-86
[2]
Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[3]
Tissue Quantification With Acoustic Radiation Force Impulse Imaging: Measurement Repeatability and Normal Values in the Healthy Liver [J].
D'Onofrio, Mirko ;
Gallotti, Anna ;
Mucelli, Roberto Pozzi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :132-136
[4]
Liver fibrosis - from bench to bedside [J].
Friedman, SL .
JOURNAL OF HEPATOLOGY, 2003, 38 :S38-S53
[5]
Real-Time Tissue Elastography Versus FibroScan for Noninvasive Assessment of Liver Fibrosis in Chronic Liver Disease [J].
Friedrich-Rust, M. ;
Schwarz, A. ;
Ong, M. ;
Dries, V. ;
Schirmacher, P. ;
Herrmann, E. ;
Samaras, P. ;
Bojunga, J. ;
Bohle, R. M. ;
Zeuzem, S. ;
Sarrazin, C. .
ULTRASCHALL IN DER MEDIZIN, 2009, 30 (05) :478-484
[6]
Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[7]
Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen [J].
Gallotti, A. ;
D'Onofrio, M. ;
Mucelli, R. Pozzi .
RADIOLOGIA MEDICA, 2010, 115 (06) :889-897
[8]
Liver Fibrosis in Patients with Chronic Hepatitis C: Noninvasive Diagnosis by Means of Real-time Tissue Elastography-Establishment of the Method for Measurement [J].
Koizumi, Yohei ;
Hirooka, Masashi ;
Kisaka, Yoshiyasu ;
Konishi, Ichiro ;
Abe, Masanori ;
Murakami, Hidehiro ;
Matsuura, Bunzo ;
Hiasa, Yoichi ;
Onji, Morikazu .
RADIOLOGY, 2011, 258 (02) :610-617
[9]
Liver stiffness in the hepatitis B virus carrier: A non-invasive marker of liver disease influenced by the pattern of transaminases [J].
Oliveri, Filippo ;
Coco, Barbara ;
Ciccorossi, Pietro ;
Colombatto, Piero ;
Romagnoli, Veronica ;
Cherubini, Beatrice ;
Bonino, Ferruccio ;
Brunetto, Maurizia Rossana .
WORLD JOURNAL OF GASTROENTEROLOGY, 2008, 14 (40) :6154-6162
[10]
Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) Imaging for the Diagnosis of Cirrhosis during Liver Ultrasonography [J].
Piscaglia, F. ;
Salvatore, V. ;
Di Donato, R. ;
D'Onofrio, M. ;
Gualandi, S. ;
Gallotti, A. ;
Peri, E. ;
Borghi, A. ;
Conti, F. ;
Fattovich, G. ;
Sagrini, E. ;
Cucchetti, A. ;
Andreone, P. ;
Bolondi, L. .
ULTRASCHALL IN DER MEDIZIN, 2011, 32 (02) :167-175