Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence

被引:48
作者
Deng, M. [1 ]
Zhao, F. [1 ]
Yuan, J. [1 ]
Ahuja, A. T. [1 ]
Wang, Y-X J. [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Imaging & Intervent Radiol, Prince Wales Hosp, Shatin, Hong Kong, Peoples R China
关键词
HEPATIC-FIBROSIS; GRADIENT-ECHO; DISEASE; RELAXATION; DIAGNOSIS; CARTILAGE; BIOPSY; COMPLICATIONS; DISPERSION; MODEL;
D O I
10.1259/bjr/98745548
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objectives: The aim of this study was to explore the technical feasibility of T-1 rho MRI for the liver, and to determine the normal range of liver T-1 rho in healthy subjects at clinical 3 T. Methods: There were 15 healthy volunteers. Three representative axial slices were selected to cut through the upper, middle and lower liver. A rotary echo spin-lock pulse was implemented in a two-dimensional fast-field echo sequence. Spin-lock frequency was 500 Hz, and the spin-lock times of 1, 10, 20, 30, 40 and 50 ms were used for T-1 rho mapping. The images were acquired slice by slice during breath-holding. Regions of interest (ROIs; n=5) were manually placed on each slice of the liver parenchyma region, excluding artefacts and vessels. The mean value of these ROIs (n=15) was regarded as the liver T-1 rho value for the subject. Six subjects were scanned once at fasting status; six subjects were scanned once 2 h post meal; three subjects were scanned twice at fasting status; and seven subjects were scanned twice 2 h post meal. Results: When two readers measured the same 10 data sets, the interreader reproducibility (ICC: intraclass correlation coefficient) was 0.955. With the 10 subjects scanned twice, the ICC for scan-rescan reproducibility was 0.764. There was no significant difference for the liver T-1 rho value at the fasting status (43.08 +/- 1.41 ms) and post-meal status (42.97 +/- 2.38 ms, p=0.867). Pooling together all the 32 scans in this study, the normal liver T-1 rho value ranged from 38.6 to 48.3 ms (mean 43.0 ms, median 42.6 ms). Conclusion: It is feasible to obtain consistent liver T-1 rho measurement for human subjects at 3 T.
引用
收藏
页码:E590 / E595
页数:6
相关论文
共 32 条
[1]
Evaluation of liver fibrosis: A concise review [J].
Afdhal, NH ;
Nunes, D .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (06) :1160-1174
[2]
Liver fibrosis: Noninvasive diagnosis with double contrast material-enhanced MR imaging [J].
Aguirre, DA ;
Behling, CA ;
Alpert, E ;
Hassanein, TI ;
Sirlin, CB .
RADIOLOGY, 2006, 239 (02) :425-437
[3]
Proteoglycan-induced changes in T1ρ-relaxation of articular cartilage at 4T [J].
Akella, SVS ;
Regatte, RR ;
Gougoutas, AJ ;
Borthakur, A ;
Shapiro, EM ;
Kneeland, JB ;
Leigh, JS ;
Reddy, R .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :419-423
[4]
[Anonymous], 1986, DESIGN ANAL CLIN EXP
[5]
Can imaging modalities diagnose and stage hepatic fibrosis and cirrhosis accurately? [J].
Bonekamp, Susanne ;
Kamel, Ihab ;
Solga, Steven ;
Clark, Jeanne .
JOURNAL OF HEPATOLOGY, 2009, 50 (01) :17-35
[6]
Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[7]
Artifacts in T1ρ-weighted imaging:: correction with a self-compensating spin-locking pulse [J].
Charagundla, SR ;
Borthakur, A ;
Leigh, JS ;
Reddy, R .
JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (01) :113-121
[8]
Nonalcoholic Fatty Liver Disease: A Review of Current Understanding and Future Impact [J].
Charlton, Michael .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2004, 2 (12) :1048-1058
[9]
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856
[10]
Projecting future complications of chronic hepatitis C in the United States [J].
Davis, GL ;
Albright, JE ;
Cook, SF ;
Rosenberg, DM .
LIVER TRANSPLANTATION, 2003, 9 (04) :331-338