Increasing sample preparation throughput using monolithic methacrylate polymer as packing material for 96-tip robotic device

被引:27
作者
Altun, Zeki
Blomberg, Lars G.
Abdel-Rehim, Mohamed [1 ]
机构
[1] AstraZeneca R&D Sodertalje, DMPK & BAC, SE-15185 Sodertalje, Sweden
[2] Karlstad Univ, Dept Chem, Karlstad, Sweden
关键词
packed; 96-tips; automated sample preparation; monolithic methacrylate; roscovitine; lidocaine; plasma; HPLC/MS/MS;
D O I
10.1080/10826070600674919
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a laboratory robot has been used to accomplish a system for high sample cleanup throughput. The robot operating in a 96-well format was furnished with 96 polypropylene tips packed with a chemically bonded monolithic methacrylate plug as sample adsorbent. Using this system, 96 samples could be handled in 2 minutes. Polypropylene tips were furnished with a chemically bonded monolithic methacrylate plug as sample adsorbent. Roscovitine and lidocaine in plasma samples were used as model substances. The validation of the methodology showed that the accuracy values of quality control samples (QC) were between +15%, and precision had a maximum deviation of 11%. The standard curve was obtained within the concentration range 145600 nM in both plasma and water samples. The regression correlation coefficients (R-2) for plasma and water samples were >= 0.999 for all runs.
引用
收藏
页码:1477 / 1489
页数:13
相关论文
共 34 条
[1]   Microextraction in packed syringe (MEPS) for liquid and gas chromatographic applications. Part II - Determination of ropivacaine and its metabolites in human plasma samples using MEPS with liquid chromatography/tandem mass spectrometry [J].
Abdel-Rehim, M ;
Altun, Z ;
Blomberg, L .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12) :1488-1493
[2]   New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry [J].
Abdel-Rehim, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :317-321
[3]   High-performance liquid chromatography-tandem electrospray mass spectrometry for the determination of lidocaine and its metabolites in human plasma and urine [J].
Abdel-Rehim, M ;
Bielenstein, M ;
Askemark, Y ;
Tyrefors, N ;
Arvidsson, T .
JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02) :175-188
[4]  
AbdelRehim M, 2003, Current Patents Gazette, P77, Patent No. [WO 03019149, 03019149, WO03019149]
[5]   SURFACE MODIFICATION OF POLYMERS .2. GRAFTING WITH GLYCIDYL ACRYLATES AND THE REACTIONS OF THE GRAFTED SURFACES WITH AMINES [J].
ALLMER, K ;
HULT, A ;
RANBY, B .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1989, 27 (05) :1641-1652
[6]   New trends in sample preparation: on-line microextraction in packed syringe (MEPS) for LC and GC applications Part III: Determination and validation of local anaesthetics in human plasma samples using a cation-exchange sorbent, and MEPS-LC-MS-MS [J].
Altun, Z ;
Abdel-Rehim, M ;
Blomberg, LG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :129-135
[7]   Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography [J].
Eeltink, S ;
Herrero-Martinez, JM ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7342-7347
[8]   Comparison of the efficiency of microparticulate and monolithic capillary columns [J].
Eeltink, S ;
Decrop, WMC ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (17-18) :1431-1440
[9]   Grafting of methyl methacrylate to cellulose and polypropylene with UV and ionising radiation in the presence of additives including CT complexes [J].
Garnett, JL ;
Ng, LT ;
Viengkhou, V .
RADIATION PHYSICS AND CHEMISTRY, 1999, 56 (04) :387-403
[10]   Sample preparation for LC/MS/MS: Analyzing biological and environmental samples [J].
Henion, J ;
Brewer, E ;
Rule, G .