Body composition analysis by leg-to-leg bioelectrical impedance and dual-energy X-ray absorptiometry in non-obese and obese individuals

被引:94
作者
Boneva-Asiova, Z. [2 ]
Boyanov, M. A. [1 ]
机构
[1] Med Univ Sofia, Alexandrovska Hosp, Endocrinol Clin, Sofia 1431, Bulgaria
[2] Cent Police Hosp, Endocrinol Unit, Sofia, Bulgaria
关键词
DXA; epidemiology; leg-to-leg BIA; obesity;
D O I
10.1111/j.1463-1326.2008.00851.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The aim of this study is to compare total weight, % body fat (% BF), fat mass ( FM) and fat-free mass (FFM) measured by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA). Methods: This cross-sectional study included 159 women (mean age: 49.1 +/- 10.0 years) and 124 men (mean age: 51.4 +/- 8.0 years) subdivided according to sex and body mass index (BMI): BMI < 30 kg/m(2) (66 women and 50 men); BMI 30-35 kg/m(2) (53 women and 44 men) and BMI >= 35 kg/m(2) (40 women and 30 men). Bioelectrical impedance was performed in the fasting state on a Tanita TBF-215 leg-to-leg analyser ( Tanita, Tokyo, Japan). Whole-body DXA scans were performed on a Hologic QDR 4500 A bone densitometer ( Hologic, Bedford, MA, USA). Total weight, % BF, FM and FFM were tested for intermethod differences. Linear regression and correlation analysis was performed. Limits of agreement and Bland-Altman plots were built. Results: DXA-derived body composition parameters were not significantly different from BIA estimates and were highly correlated (e.g. for FFM, r = 0.82-0.95). In lean individuals, BIA tended to produce lower values for FM and % BF and higher ones for FFM in comparison with DXA. This trend was reversed at BMI > 35 kg/m(2). The correlations decreased with increasing BMI. The limits of agreement were much better in men than in women and increased with increasing BMI in both sexes. Conclusions: Compared with DXA, the leg-to-leg Tanita TBF-215 analyser accurately assessed body composition in a heterogeneous group of both sexes. In the very obese women (BMI > 35 kg/m(2)), BIA measurements should be viewed with caution.
引用
收藏
页码:1012 / 1018
页数:7
相关论文
共 30 条
[1]  
Andreoli A, 2002, J SPORT MED PHYS FIT, V42, P186
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Demura S, 2005, J SPORT MED PHYS FIT, V45, P68
[4]  
DEURENBERG P, 1989, EUR J CLIN NUTR, V43, P647
[5]   CHANGES IN FAT-FREE MASS DURING WEIGHT-LOSS MEASURED BY BIOELECTRICAL IMPEDANCE AND BY DENSITOMETRY [J].
DEURENBERG, P ;
WESTSTRATE, JA ;
HAUTVAST, JGAJ .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (01) :33-36
[6]   The validity of predicted body fat percentage from body mass index and from impedance in samples of five European populations [J].
Deurenberg, P ;
Andreoli, A ;
Borg, P ;
Kukkonen-Harjula, K ;
de Lorenzo, A ;
Lichtenbelt, WDV ;
Testolin, G ;
Vigano, R ;
Vollaard, N .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2001, 55 (11) :973-979
[7]  
Deurenberg Paul, 1996, American Journal of Clinical Nutrition, V64, p449S, DOI 10.1093/ajcn/64.3.449S
[8]  
Dixon CB, 2005, J STRENGTH COND RES, V19, P85
[9]   Comparison of methods to assess body composition changes during a period of weight loss [J].
Frisard, MI ;
Greenway, FL ;
DeLany, JP .
OBESITY RESEARCH, 2005, 13 (05) :845-854
[10]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270