Factors associated with early failure of arteriovenous fistulae for haemodialysis access

被引:336
作者
Wong, V [1 ]
Ward, R [1 ]
Taylor, J [1 ]
Selvakumar, S [1 ]
How, TV [1 ]
Bakran, A [1 ]
机构
[1] UNIV LIVERPOOL,ROYAL LIVERPOOL HOSP,RENAL TRANSPLANT UNIT,LIVERPOOL L7 8XP,MERSEYSIDE,ENGLAND
关键词
radial artery; cephalic vein; size; blood flow; Duplex ultrasound;
D O I
10.1016/S1078-5884(96)80108-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up ions performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 13 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]  
ANDERSON CB, 1977, SURG GYNECOL OBSTET, V144, P531
[3]   PULSE-GENERATED RUNOFF - A NEW METHOD OF DETERMINING CALF VESSEL PATENCY [J].
BEARD, JD ;
SCOTT, DJA ;
EVANS, JM ;
SKIDMORE, R ;
HORROCKS, M .
BRITISH JOURNAL OF SURGERY, 1988, 75 (04) :361-363
[4]  
BITKER MO, 1984, ANN UROL, V18, P98
[6]  
HAIMOV M, 1975, SURG GYNECOL OBSTET, V141, P619
[7]   9 YEARS EXPERIENCE WITH INTERNAL ARTERIOVENOUS-FISTULAS FOR HEMODIALYSIS - STUDY OF SOME FACTORS INFLUENCING RESULTS [J].
KINNAERT, P ;
VEREERSTRAETEN, P ;
TOUSSAINT, C ;
VANGEERTRUYDEN, J .
BRITISH JOURNAL OF SURGERY, 1977, 64 (04) :242-246
[8]  
McDonald D. A., 1974, BLOOD FLOW ARTERIES
[9]   COLOR DOPPLER SONOGRAPHY OF HEMODIALYSIS VASCULAR ACCESS - COMPARISON WITH ANGIOGRAPHY [J].
MIDDLETON, WD ;
PICUS, DD ;
MARX, MV ;
MELSON, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :633-639
[10]   COLOR DOPPLER ULTRASOUND ASSESSMENT OF ARTERIOVENOUS HEMODIALYSIS FISTULAS [J].
NONNASTDANIEL, B ;
MARTIN, RP ;
LINDERT, O ;
MUGGE, A ;
SCHAEFFER, J ;
SOCHTIG, E ;
GALANSKI, M ;
KOCH, KM ;
DANIEL, WG ;
VANDERLIETH, H .
LANCET, 1992, 339 (8786) :143-145