From time dependent intermittent selfcatheterisation to volume dependent selfcatheterisation in Multiple Sclerosis using the PCI 5000 Bladdermanager(R)

被引:20
作者
DeRidder, D
VanPoppel, H
Baert, L
Binard, J
机构
[1] KATHOLIEKE UNIV LEUVEN,B-3001 LOUVAIN,BELGIUM
[2] NATL CTR MULTIPLE SCLEROSIS,MELSBROEK,BELGIUM
[3] UNIV S FLORIDA,TAMPA,FL 33620
关键词
Multiple sclerosis; intermittent selfcatheterisation; neuropathic bladder; ultrasound;
D O I
10.1038/sj.sc.3100446
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The use of portable, patient controlled, ultrasound device for the measurement of the bladder volume (PCI 5000, Bladdermanager(R)) in the management of neurogenic bladder dysfunction in Multiple Sclerosis is presented. Twenty-three patients were transferred from time dependent intermittent catheterisation to volume dependent intermittent catheterisation using this device. Evaluation of the accuracy of the measurements showed an accuracy of 91.05%. The efficacy per catheterisation improved significantly from 260.8 cc +/- 154 cc to 297.5 cc +/- 138 cc. The frequency of incontinence measured during 48 h decreased on the entire group from 69 to 39. Six patients could delete one catheterisation a day. Functional Independence Measurements (FIM score) did not show an increase of the level of assistance needed, using this device.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 7 条
[1]  
Binard J E, 1996, J Spinal Cord Med, V19, P194
[2]   THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME [J].
COOMBES, GM ;
MILLARD, RJ .
JOURNAL OF UROLOGY, 1994, 152 (06) :2083-2085
[3]   TREATMENT OF LOWER URINARY-TRACT DYSFUNCTION IN PATIENTS WITH MULTIPLE-SCLEROSIS [J].
FOWLER, CJ ;
VANKERREBROECK, PEV ;
NORDENBO, A ;
VANPOPPEL, H .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1992, 55 (11) :986-989
[4]   EFFICIENT TREATMENT OF NEUROGENIC BLADDER DISORDERS IN MULTIPLE-SCLEROSIS WITH INITIAL INTERMITTENT CATHETERIZATION AND ULTRASOUND-CONTROLLED TRAINING [J].
KORNHUBER, HH ;
SCHUTZ, A .
EUROPEAN NEUROLOGY, 1990, 30 (05) :260-267
[5]   EXPERIENCE WITH PORTABLE ULTRASOUND EQUIPMENT AND MEASUREMENT OF URINE VOLUMES - INTER-USER RELIABILITY AND FACTORS OF PATIENT POSITION [J].
MASSAGLI, TL ;
CARDENAS, DD ;
KELLY, EW .
JOURNAL OF UROLOGY, 1989, 142 (04) :969-971
[6]  
*STAT U NEW YORK, 1993, GUID UN DAT SET MED
[7]   NEUROMUSCULAR DYSFUNCTION OF THE LOWER URINARY-TRACT IN MULTIPLE-SCLEROSIS [J].
VANPOPPEL, H ;
VEREECKEN, RL ;
LERUITTE, A .
PARAPLEGIA, 1983, 21 (06) :374-379