First and third trimester ultrasound in the prediction of birthweight discordance in dichorionic twins

被引:37
作者
Banks, Claire L. [1 ]
Nelson, Scott M. [2 ]
Owen, Philip [1 ]
机构
[1] Glasgow Royal Infirm, Princess Royal Mat Unit, Dept Obstet & Gynaecol, Glasgow G31 2ER, Lanark, Scotland
[2] Univ Glasgow, Glasgow G31 2ER, Lanark, Scotland
来源
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY | 2008年 / 138卷 / 01期
关键词
twins; birthweight discordance; first trimester ultrasound biometry; third trimester estimated fetal weight; fetal growth velocity;
D O I
10.1016/j.ejogrb.2007.08.004
中图分类号
R71 [妇产科学];
学科分类号
100211 [妇产科学];
摘要
Objective: Birthweight discordance amongst twins is associated with an increase in perinatal morbidity and mortality. Clinical decisions regarding the management of twins are often made on the basis of estimated fetal weight in the third trimester. This study assesses the efficacy of routine third trimester ultrasound fetal biometry, third trimester fetal growth velocity and first trimester differences in size in the prediction of subsequent birthweight discordance. Study design: Structurally and chromosomally normal dichorionic twin gestations resulting in two live births after 24 weeks gestation were identified. Ultrasound examinations of dichorionic twin pregnancies between 10 and 14 weeks of gestation were evaluated for inter-twin biometric disparity in crown-rump length (CRL). Estimated fetal weight (EFW) was calculated from the last scan before delivery. Fetal growth velocity (FGV) was calculated from two estimates of fetal weight between 21 and 35 days apart and incorporating the last EFW before delivery. EFW and FGV were expressed as standard deviation scores (Z scores). Disparity between these ultrasound parameters was correlated to inter-twin birthweight difference. Birthweight discordance was defined as >= 20% difference in birthweight relative to the heavier twin. Fishers exact and Spearman rho tests were used for statistical analysis. Test performance is expressed as area under the ROC curve and likelihood ratios (LR). Results: One hundred and thirty-five dichorionic gestations were identified over a consecutive 3-year-period. One hundred and eight twin gestations had both crown-rump length (CRL) and sufficient ultrasound measurements in the third trimester to calculate FGV. Twenty-six pregnancies (24%) had discordant birthweight. Only EFW Z score difference was correlated with birthweight disparity (r = 0.36, p = < 0.001). An EFW Z score difference of 0.6 had an area under the ROC curve of 0.70 (95% C.I. 0.59-0.79) but this did not differ significantly from first trimester prediction of growth discordance which had an area of 0.55 (95% C.I. 0.44-0.66). The LR for first and third trimester prediction of discordance were low. Conclusion: Ultrasound measurement of fetal growth velocity and size both in the first and third trimesters is a poor predictor of birthweight discordance. Disparate fetal growth is exhibited as early as 10-14 weeks gestation and differences at this early stage in fetal development are no less accurate than EFW within 1 month of delivery. First trimester ultrasound, third trimester growth velocity and third trimester EFW do not accurately predict the delivery of twins with discordant birthweight. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 29 条
[1]
Neonatal mortality rates among growth-discordant twins, classified according to the birth weight of the smaller twin [J].
Blickstein, I ;
Keith, LG .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 190 (01) :170-174
[2]
Sonographic examination does not predict twin growth discordance accurately [J].
Caravello, JW ;
Chauhan, SP ;
Morrison, JC ;
Magann, EF ;
Martin, JN ;
Devoe, LD .
OBSTETRICS AND GYNECOLOGY, 1997, 89 (04) :529-533
[3]
Sonographic prediction of significant intertwin birth weight discordance [J].
Chang, Yao-Lung ;
Chang, Ting-Chang ;
Chang, Shuenn-Dyh ;
Cheng, Po-Jen ;
Chao, An-Shine ;
Hsieh, Peter C. C. ;
Soong, Yung-Kuei .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2006, 127 (01) :35-40
[4]
Chauhan SP, 1996, J REPROD MED, V41, P403
[5]
Validity of ultrasound estimation of fetal weight [J].
Chien, PFW ;
Owen, P ;
Khan, KS .
OBSTETRICS AND GYNECOLOGY, 2000, 95 (06) :856-860
[6]
Prediction of discordant twins by real-time ultrasonography combined with umbilical artery velocimetry [J].
Chittacharoen, A ;
Leelapattana, P ;
Rangsiprakarn, R .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 15 (02) :118-121
[7]
Chittacharoen A, 1999, J Obstet Gynaecol Res, V25, P95
[8]
Fetal and neonatal mortality among twin gestations in the United States: The role of intrapair birth weight discordance [J].
Demissie, K ;
Ananth, CV ;
Martin, J ;
Hanley, ML ;
MacDorman, MF ;
Rhoads, GG .
OBSTETRICS AND GYNECOLOGY, 2002, 100 (03) :474-480
[9]
INCIDENCE AND SIGNIFICANCE OF UNEQUAL GESTATIONAL SAC DIAMETER OR EMBRYO CROWN RUMP LENGTH IN TWIN PREGNANCY [J].
DICKEY, RP ;
OLAR, TT ;
TAYLOR, SN ;
CUROLE, DN ;
RYE, PH ;
MATULICH, EM ;
DICKEY, MH .
HUMAN REPRODUCTION, 1992, 7 (08) :1170-1172
[10]
DIVON MY, 1990, AM J OBSTET GYNECOL, V163, P1100