Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study

被引:200
作者
Martin, S
Schneider, B
Heinemann, L
Lodwig, V
Kurth, HJ
Kolb, H
Scherbaum, W
机构
[1] Univ Dusseldorf, German Diabet Clin, German Diabet Ctr, D-40225 Dusseldorf, Germany
[2] Hanover Med Univ, Inst Biometry, Hannover, Germany
[3] Profil Inst Metab Res, Neuss, Germany
[4] Inst Med Informat & Biostat, Basel, Switzerland
关键词
blood glucose; cohort study; long-term outcome; observational study; retrospective; self-monitoring; SMBG; type; 2; diabetes;
D O I
10.1007/s00125-005-0083-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/hypothesis: The aim of this study was to obtain epidemiological data on self-monitoring of blood glucose (SMBG) in type 2 diabetes and to investigate the relationship of SMBG with disease-related morbidity and mortality. Methods: The German multicentre Retrolective Study 'Self-monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes' (ROSSO) followed 3,268 patients from diagnosis of type 2 diabetes between 1995 and 1999 until the end of 2003. Endpoints were diabetes-related morbidity (non-fatal myocardial infarction, stroke, foot amputation, blindness or haemodialysis) and all-cause mortality. SMBG was defined as self-measurement of blood glucose for at least 1 year. Results: During a mean follow-up period of 6.5 years, 1,479 patients (45.3%) began SMBG prior to an endpoint and an additional 64 patients started SMBG after a non-fatal endpoint. Interestingly, many patients used SMBG while being treated with diet or oral hypoglycaemic drugs ( 808 of 2,515, 32%). At baseline, the SMBG cohort had higher mean fasting blood glucose levels than the non-SMBG cohort (p< 0.001), suggesting that insufficient metabolic control was one reason for initiating SMBG. This was associated with a higher rate of microvascular endpoints. However, the total rate of nonfatal events, micro- and macrovascular, was lower in the SMBG group than in the non-SMBG group (7.2 vs 10.4%, p= 0.002). A similar difference was found for the rate of fatal events (2.7 vs 4.6%, p= 0.004). Cox regression analysis identified SMBG as an independent predictor of morbidity and mortality, with adjusted hazard ratios of 0.68 (95% CI 0.51 - 0.91, p= 0.009) and 0.49 ( 95% CI 0.31 - 0.78, p= 0.003), respectively. A better outcome for both endpoints was also observed in the SMBG cohort when only those patients who were not receiving insulin were analysed. Conclusions/interpretation: SMBG was associated with decreased diabetes-related morbidity and all-cause mortality in type 2 diabetes, and this association remained in a subgroup of patients who were not receiving insulin therapy. SMBG may be associated with a healthier lifestyle and/or better disease management.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 33 条
  • [1] IMPACT OF GLUCOSE SELF-MONITORING ON NON-INSULIN-TREATED PATIENTS WITH TYPE-II DIABETES-MELLITUS - RANDOMIZED CONTROLLED TRIAL COMPARING BLOOD AND URINE TESTING
    ALLEN, BT
    DELONG, ER
    FEUSSNER, JR
    [J]. DIABETES CARE, 1990, 13 (10) : 1044 - 1050
  • [2] Nurse case management to improve glycemic control in diabetic patients in a health maintenance organization - A randomized, controlled trial
    Aubert, RE
    Herman, WH
    Waters, J
    Moore, W
    Sutton, D
    Peterson, BL
    Bailey, CM
    Koplan, JP
    [J]. ANNALS OF INTERNAL MEDICINE, 1998, 129 (08) : 605 - +
  • [3] SELF-MONITORING OF BLOOD-GLUCOSE LEVELS IN NON-INSULIN-DEPENDENT DIABETES-MELLITUS
    COHEN, M
    ZIMMET, P
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 1983, 2 (08) : 377 - 380
  • [4] Self-monitoring in Type 2 diabetes mellitus: a meta-analysis
    Coster, S
    Gulliford, MC
    Seed, PT
    Powrie, JK
    Swaminathan, R
    [J]. DIABETIC MEDICINE, 2000, 17 (11) : 755 - 761
  • [5] Coster S, 2000, HEALTH TECHNOL ASSES, V4, P1, DOI DOI 10.3310/hta4120
  • [6] Counterpoint: Self-monitoring of blood glucose in type 2 diabetic patients not receiving insulin: A waste of money
    Davidson, MB
    [J]. DIABETES CARE, 2005, 28 (06) : 1531 - 1533
  • [7] The efficacy of self-monitoring of blood glucose in NIDDM subjects - A criteria-based literature review
    Faas, A
    Schellevis, FG
    vanEijk, JTM
    [J]. DIABETES CARE, 1997, 20 (09) : 1482 - 1486
  • [8] FONTBONNE A, 1989, DIABETES METAB, V15, P255
  • [9] The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients - An urgent need for better educational strategies
    Franciosi, M
    Pellegrini, F
    De Berardis, G
    Belfiglio, M
    Cavaliere, D
    Di Nardo, B
    Greenfield, S
    Kaplan, SH
    Sacco, M
    Tognoni, G
    Valentini, M
    Nicolucci, A
    [J]. DIABETES CARE, 2001, 24 (11) : 1870 - 1877
  • [10] Tests of glycemia in diabetes
    Goldstein, DE
    Little, RR
    Lorenz, RA
    Malone, JI
    Nathan, D
    Peterson, CM
    Sacks, DB
    [J]. DIABETES CARE, 2004, 27 (07) : 1761 - 1773