On-line diagnostic tools for CMM performance

被引:10
作者
Franceschini, F [1 ]
Galetto, M [1 ]
Settineri, L [1 ]
机构
[1] Politecn Torino, Dipartimento Sistemi Prod & Econ Azienda, I-10129 Turin, Italy
关键词
CMM performances; control charts; on-line diagnostics; quality;
D O I
10.1007/s001700200005
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The on-line evaluation of the degradation of a coordinate measuring machine (CAM) performance, either due to variations of environmental factors, or to the deterioration of one of the CMM subsystems, is particularly important for the machine user. A sign of this interest is the large number of international standards that have been issued. The paper presents an approach for the on-line diagnostic of the metrological capabilities of a CMM. The method, which does not make use of additional internal or external instrumentation, is performed on-line during a normal measurement cycle. The graphical approach of the method, based on the use of control charts, permits a simple and immediate monitoring of the machine performance. Preliminary experimental results are presented and discussed.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 21 条
[11]   Control charts for the on-line diagnostics of CMM performances [J].
Franceschini, F ;
Settineri, L .
INTERNATIONAL JOURNAL OF COMPUTER INTEGRATED MANUFACTURING, 2000, 13 (02) :148-156
[12]  
FRANCESCHINI F, 1994, 1 C ART INT TECHN EN, P225
[13]  
*ISO, 1994, 103602 ISO
[14]  
(ISO) International Organization for Standardization, 1992, 100121 ISO
[15]   COMPARISON OF DIFFERENT ARTIFACTS FOR INTERIM COORDINATE-MEASURING MACHINE CHECKING - A REPORT FROM THE SWISS-STANDARDS-COMMITTEE [J].
KNAPP, W ;
TSCHUDI, U ;
BUCHER, A .
PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1991, 13 (04) :277-291
[16]  
Montgomery DC., 1996, INTRO STAT QUALITY C, V3rd
[17]  
OKSMAN J, 1993, 6 C INT METR LILL 19, P224
[18]  
Pau L, 1981, FAILURE DIAGNOSIS PE
[19]  
Raz T., 1992, Production Planning and Control, V3, P48, DOI 10.1080/09537289208919372
[20]  
Reznik L. K., 1985, Measurement, V3, P98, DOI 10.1016/0263-2241(85)90013-2