Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients

被引:53
作者
Sander, M
von Heymann, C
Foer, A
von Dossow, V
Grosse, J
Dushe, S
Konertz, WF
Spies, CD
机构
[1] Univ Hosp Charite, Univ Med, Dept Anesthesiol & Intens Care Med, D-10098 Berlin, Germany
[2] Univ Hosp Charite, Univ Med, Dept Cardiovasc Surg, D-10098 Berlin, Germany
来源
CRITICAL CARE | 2005年 / 9卷 / 06期
关键词
D O I
10.1186/cc3903
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Monitoring of the cardiac output by continuous arterial pulse contour ( COPiCCOpulse) analysis is a clinically validated procedure proved to be an alternative to the pulmonary artery catheter thermodilution cardiac output (COPACtherm) in cardiac surgical patients. There is ongoing debate, however, of whether the COPiCCOpulse is accurate after profound hemodynamic changes. The aim of this study was therefore to compare the COPiCCOpulse after cardiopulmonary bypass (CPB) with a simultaneous measurement of the COPACtherm. Methods After ethical approval and written informed consent, data of 45 patients were analyzed during this prospective study. During coronary artery bypass graft surgery, the aortic transpulmonary thermodilution cardiac output (COPiCCOtherm) and the COPACtherm were determined in all patients. Prior to surgery, the COPiCCOpulse was calibrated by triple transpulmonary thermodilution measurement of the COPiCCOtherm. After termination of CPB, the COPiCCOpulse was documented. Both COPACtherm and COPiCCOtherm were also simultaneously determined and documented. Results Regression analysis between COPACtherm and COPiCCOtherm prior to CPB showed a correlation coefficient of 0.95 ( P < 0.001), and after CPB showed a correlation coefficient of 0.82 ( P < 0.001). Bland-Altman analysis showed a mean bias and limits of agreement of 0.0 l/ minute and - 1.4 to + 1.4 l/ minute prior to CPB and of 0.3 l/ minute and - 1.9 to + 2.5 l/ minute after CPB, respectively. Regression analysis of COPiCCOpulse versus COPiCCOtherm and of COPiCCOpulse versus COPACtherm after CPB showed a correlation coefficient of 0.67 ( P < 0.001) and 0.63 ( P < 0.001), respectively. Bland-Altman analysis showed a mean bias and limits of agreement of - 1.1 l/ minute and - 1.9 to + 4.1 l/ minute versus - 1.4 l/ minute and - 4.8 to + 2.0 l/ minute, respectively. Conclusion We observed an excellent correlation of COPiCCOtherm and COPACtherm measurement prior to CPB. Pulse contour analysis did not yield reliable results with acceptable accuracy and limits of agreement under difficult conditions after weaning from CPB in cardiac surgical patients. The pulse contour analysis thus should be re-calibrated as soon as possible, to prevent false therapeutic consequences.
引用
收藏
页码:R729 / R734
页数:6
相关论文
共 21 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Buhre G, 1999, J CARDIOTHOR VASC AN, V13, P437
[3]   INTERMITTENT ANTEGRADE WARM BLOOD CARDIOPLEGIA [J].
CALAFIORE, AM ;
TEODORI, G ;
MEZZETTI, A ;
BOSCO, G ;
VERNA, AM ;
DIGIAMMARCO, G ;
LAPENNA, D .
ANNALS OF THORACIC SURGERY, 1995, 59 (02) :398-402
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]   Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique [J].
Della Rocca, G ;
Costa, MG ;
Pompei, L ;
Coccia, C ;
Pietropaoli, P .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) :350-356
[6]   Continuous, less invasive, hemodynamic monitoring in intensive care after cardiac surgery [J].
Godje, O ;
Hoke, K ;
Lamm, P ;
Schmitz, C ;
Thiel, C ;
Weinert, M ;
Reichart, B .
THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (04) :242-249
[7]  
Godje O, 2001, Med Sci Monit, V7, P1344
[8]  
Gödje O, 2002, CRIT CARE MED, V30, P52
[9]   Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial [J].
Harvey, S ;
Harrison, DA ;
Singer, M ;
Ashcroft, J ;
Jones, CM ;
Elbourne, D ;
Brampton, W ;
Williams, D ;
Young, D ;
Rowan, K .
LANCET, 2005, 366 (9484) :472-477
[10]   CONTINUOUS CARDIAC-OUTPUT MONITORING BY PULSE CONTOUR DURING CARDIAC-SURGERY [J].
JANSEN, JRC ;
WESSELING, KH ;
SETTELS, JJ ;
SCHREUDER, JJ .
EUROPEAN HEART JOURNAL, 1990, 11 :26-32