Improved detection of multi-phosphorylated peptides in the presence of phosphoric acid in liquid chromatography/mass spectrometry

被引:71
作者
Kim, J [1 ]
Camp, DG [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 02期
关键词
phosphopeptides; reversed-phase liquid chromatography; mass spectrometry; bovine beta-casein; silanophilic interaction;
D O I
10.1002/jms.593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In contrast to lower phosphorylation states (e.g. the tryptic monophosphopeptide FQpSEEQQQTEDELQDK from bovine beta-casein), the specific detection of multi-phosphorylated peptides (e.g. the tetraphosphopeptide RELEELNVPGEIVEpSLpSpSpSEESITR from tryptic digestion of bovine P-casein) has often been problematic for liquid chromatographic mass spectrometric (LC/MS) analysis owing to their high affinity for adsorption to exposed surfaces. We observed an enhancement in the overall detection of phosphopeptides on addition of phosphoric acid (0.1-1.0%) to the sample solution; a 10-fold increase in sensitivity was determined for the detection of two tryptic phosphopeptides and also a significant improvement in the detection of the tetraphosphopeptide. Using capillary LC with ion trap tandem MS for detection and identification, the achievable detection limits were 50 fmol and 50 pmol for the monophosphopeptide and the tetraphosphopeptide, respectively. Phosphoric acid is believed to act as a blocking agent to available silanol groups on both the silica capillary surface and the C-18-bonded stationary phase silica surface. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:208 / 215
页数:8
相关论文
共 45 条
[1]  
Allen M, 1997, RAPID COMMUN MASS SP, V11, P325
[2]   Alkaline liquid chromatography/electrospray ionization skimmer collision-induced dissociation mass spectrometry for phosphopeptide screening [J].
Beck, A ;
Deeg, M ;
Moeschel, K ;
Schmidt, EK ;
Schleicher, ED ;
Voelter, WG ;
Häring, HU ;
Lehmann, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (23) :2324-2333
[3]   Phosphopeptide detection and sequencing by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry [J].
Bennett, KL ;
Stensballe, A ;
Podtelejnikov, AV ;
Moniatte, M ;
Jensen, ON .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (02) :179-190
[4]  
BOGUSZ M, 1992, J LIQ CHROMATOGR, V15, P127
[5]  
Cao P, 2000, RAPID COMMUN MASS SP, V14, P1600, DOI 10.1002/1097-0231(20000915)14:17<1600::AID-RCM68>3.0.CO
[6]  
2-V
[7]   Selective detection and sequencing of phosphopeptides at the femtomole level by mass spectrometry [J].
Carr, SA ;
Huddleston, MJ ;
Annan, RS .
ANALYTICAL BIOCHEMISTRY, 1996, 239 (02) :180-192
[8]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[9]   HYDROGEN-ION EQUILIBRIA OF BOVINE BETA-CASEIN-B [J].
CREAMER, LK .
BIOCHIMICA ET BIOPHYSICA ACTA, 1972, 271 (02) :252-+
[10]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989